𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Integration of press-fit implants in cortical bone: A study on interface kinetics

✍ Scribed by Dhert, W. J. A. ;Thomsen, P. ;Blomgren, A. K. ;Esposito, M. ;Ericson, L. E. ;Verbout, A. J.


Publisher
John Wiley and Sons
Year
1998
Tongue
English
Weight
659 KB
Volume
41
Category
Article
ISSN
0021-9304

No coin nor oath required. For personal study only.

✦ Synopsis


The early healing phase of hard tissue implants is important to their long-term success. Problems during this phase can result in a so-called primary biological failure. In 24 New Zealand white rabbits, the healing in cortical bone of noncoated TiAlV and cpTi cylinders and of TiAlV cylinders plasma-spray-coated with hydroxyapatite (HA) of fluorapatite (FA) was investigated histologically and histomorphometrically after 3, 7, 14, and 28 days. Histomorphometry consisted of bone contact measurements and the use of a new semi quantitative scoring system that discriminated various tissues in contact with the implant. The results demonstrated that the most important parameter in initial implant healing is the bone itself and not the characteristics of the implanted material. For all implants, healing was characterized by a sequence of hematoma formation, bone resorption, and new bone formation where the initial press-fit situation revealed more bone-implant contact than after 7 and 14 days. There were only minor differences between the implant types: the new bone formation directly on the implant surface was qualitatively histologically superior to the CaP-coated implants, but this could be confirmed with the scoring method only for the HA-coated implants. It is concluded that initial press-fit fixation in cortical bones is not an end situation; rather, what happens is that as a result of interface remodeling, early postoperatively implant integration in the bone will decrease temporarily prior to a subsequent phase of new bone formation.


πŸ“œ SIMILAR VOLUMES


A light and laser scanning microscopy st
✍ Piattelli, Adriano ;Trisi, Paolo πŸ“‚ Article πŸ“… 1994 πŸ› John Wiley and Sons 🌐 English βš– 900 KB

The authors describe a light and laser scanning microscopy study of hydroxyapatite-coated titanium implants retrieved from humans. A histochemical technique, using von Kossa and basic fuchsin, allowed clear differentiation between mineralized bone and unmineralized bone matrix. The bone-hydroxyapati

The effect of alendronate (Fosamax?) and
✍ Frenkel, Sally R. ;Jaffe, William L. ;Valle, Craig Della ;Jazrawi, Laith ;Maurer πŸ“‚ Article πŸ“… 2001 πŸ› John Wiley and Sons 🌐 English βš– 278 KB πŸ‘ 1 views

## Abstract Patients at high risk for osteoporosis and its associated morbidity, including postmenopausal women, are being pharmacologically managed to stabilize and improve bone mass. Alendronate sodium (Fosamaxβ„’) is a commonly used antiresorptive agent effective in osteopenic women for reducing b

A novel multiphase anodic spark depositi
✍ Gianluca Giavaresi; Milena Fini; Roberto Chiesa; Carmen Giordano; Enrico Sandrin πŸ“‚ Article πŸ“… 2008 πŸ› John Wiley and Sons 🌐 English βš– 502 KB

## Abstract The effect of a new three‐step anodic spark deposition process, labeled TiSpark, including two consecutive treatments performed first in a P solution and second in Ca solution, followed by an additional alkali etching step, was investigated for the improvement of osseointegration of com

Influence of direct laser fabrication im
✍ Jamil Awad Shibli; Carlo Mangano; Susana D'avila; Adriano Piattelli; Gabriele E. πŸ“‚ Article πŸ“… 2009 πŸ› John Wiley and Sons 🌐 English βš– 528 KB

## Abstract The aim of this histologic study was to evaluate the influence of the direct laser fabrication (DFL) surface topography on bone‐to‐implant contact (BIC%), on bone density in the threaded area (BA%) as well as bone density outside the threaded area (BD%) in type IV bone after 8 weeks of

Effects of fixation technique on displac
✍ Aivars Berzins; Dale R. Sumner; Thomas M. Turner; Raghu Natarajan πŸ“‚ Article πŸ“… 1994 πŸ› Wiley (John Wiley & Sons) 🌐 English βš– 491 KB πŸ‘ 2 views

Bone-implant displacements can be caused by rigid body motion and by differences in material properties of the implant and bone. In the present study of the tibial component in total knee replacement, we tested a series of tibial component fixation designs to determine how certain design features in