𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Integral diagnostic in the failure causes of external corrosion of a natural gas transport pipeline

✍ Scribed by J. L. Mora-Mendoza; L. C. Saucedo-Robles; H. Rodríguez-Clemente; M. A. González-Núñez; G. Zavala-Olivares; M. J. Hernández-Gayosso


Publisher
John Wiley and Sons
Year
2010
Tongue
German
Weight
427 KB
Volume
62
Category
Article
ISSN
0947-5117

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

The objective of this study consisted in investigating the possible causes which give rise to the presence of low wall pipe thicknesses on a 16″ natural gas transport pipeline, even though during the last 12‐year period cathodic protection (CP) potentials were kept in the protection range at which external corrosion should not occur. Results from in‐line inspection from a 16″ natural gas transport pipeline showed 46 indications with more than 80% wall thickness lost due to external corrosion in the second segment of the pipeline. Direct inspection at the indication locations, review of the CP system performance, pipeline maintenance programs and studies, allowed to make an integral diagnostic where it was found out that the main cause of external corrosion was an inappropriate coating application since the pipeline construction, this situation has originated the increase of CP shielding effects through time.