## Abstract A lensed fiber collimator using gradient‐index fiber (GIF) of 140 μm diameter spliced to single‐mode fiber (SMF) is reported. The complex beam parameter method and ABCD law are applied for theoretical analysis. Both numerical and experimental data are presented for optical characterizat
Insertion loss of lensed fiber collimator with larger gradient-index lens diameter
✍ Scribed by Yu-Cheng Lin
- Book ID
- 102521379
- Publisher
- John Wiley and Sons
- Year
- 2010
- Tongue
- English
- Weight
- 443 KB
- Volume
- 52
- Category
- Article
- ISSN
- 0895-2477
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
The insertion loss of lensed fiber collimator using gradient‐index fiber of 140‐μm diameter spliced to single‐mode fiber is investigated. The power transmission equation is applied for theoretical analysis of the insertion loss between a lensed fiber pair. Both numerical and experimental data are presented in axial and lateral displacement. The optimum coupling position 600 μm for 0.29‐pitch lensed fiber and the maximum working distance 1027 μm for 0.27‐pitch lensed fiber are demonstrated. © 2010 Wiley Periodicals, Inc. Microwave Opt Technol Lett 52: 1235–1238, 2010; Published online in Wiley InterScience (www.interscience.wiley.com). DOI 10.1002/mop.25171
📜 SIMILAR VOLUMES