Injection temperature effects using On-column and split sampling in capillary gas chromatography

✍ Scribed by Wang, F.-S. ;Shanfield, H. ;Zlatkis, A.


Publisher
John Wiley and Sons
Year
1983
Tongue
English
Weight
573 KB
Volume
6
Category
Article
ISSN
0935-6304

No coin nor oath required. For personal study only.

✦ Synopsis


The effect of sample injection temperature on quantitation is examined for on-column and conventional split modes of sampling in capillary gas chromatography. Discrimination effects can be observed even with on-column injection if the injection temperature is too far above the boiling point of the solvent (or that of a major low boiling constituent). This is attributed to higher boiling components being left behind in the syringe needle, and a set of simulation experiments are described to illustrate this effect. Various discrimination patterns using conventional split injection were observed, depending on temperature of injection. Apart from syringe needle effects, discrimination is probably due to the preferential venting of higher boiling components as liquid sample droplets, which can havea lifetimegreaterthan thetimeof transit to thesplitter. With such a two-phase system, involving variable droplet size, the flow distribution in the splitter will be critical to uniform sampling. The use of combination on-column/split sampling, with the appropriate temperature control to provide sample uniformity to the splitter is discussed as an advantageous alternative to conventional split sampling.


πŸ“œ SIMILAR VOLUMES


Determination of polynuclear aromatic hy
✍ Morabito, Paul L. ;McCabe, Terry ;Hiller, Joseph F. ;Zakett, Don πŸ“‚ Article πŸ“… 1993 πŸ› John Wiley and Sons 🌐 English βš– 426 KB

## Abstract An automated large volume on‐column injection technique for capillary gas chromatography (GC) with solvent divert and heated retention gap technology has been utilized to determine polynuclear aromatic hydrocarbons (PAHs) in samples of industrial plant process water. Injecting large sam

Increased on-column injection temperatur
✍ JanΓ‘k, Karel ;ColmsjΓΆ, Anders ;Γ–stman, Conny πŸ“‚ Article πŸ“… 1995 πŸ› John Wiley and Sons 🌐 English βš– 441 KB

## Abstract A way of controlling the maximum allowable oven temperature during on‐column injection by the column pressure drop is suggested. An arrangement using a restriction at the column outlet for adjustment of the column inlet pressure while maintaining the same column flow has been studied. C