𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Influence of trapping parameters on ion injection and dissociation efficiencies in a quadrupole mass filter/ion trap tandem instrument

✍ Scribed by Steiner, V.; Beaugrand, C.; Liere, P.; Tabet, J.-C.


Publisher
John Wiley and Sons
Year
1999
Tongue
English
Weight
206 KB
Volume
34
Category
Article
ISSN
1076-5174

No coin nor oath required. For personal study only.

✦ Synopsis


Investigations on ion injection into a laboratory-built quadrupole/ion trap tandem instrument (Nermag R10-10/ITMS Finnigan) with a 90Ä geometry are described. The quadrupole dual electron impact/chemical ionization (EI/CI) source was used as an external source to prepare ions under EI (or CI) conditions. They were selected by the quadrupole analyzer and injected into the ion trap by using an electrostatic quadrupolar deÑector. The e †ects of major trapping parameters (i.e. ion injection r.f. level and helium pressure) were considered. The injection efficiency of the stable (m/z 69) fragment ion from FC43 and also those of the m/z 40 and 84 atomic cations of argon CF 3 ' and krypton depend upon the injection r.f. level conditions. As expected, e †ects of non-linear resonances were observed during these experiments. Under certain injection and trapping conditions, ion motion can be strongly a †ected, yielding ion ejection, because non-linear Ðelds (resulting from device imperfections) are present in addition to the quadrupolar potential required for ion trapping. The inÑuences of non-linear e †ects according to their strength were investigated to show the best and worst trapping conditions. The non-linear resonances are characterized by the expected values. In order to determine the average internal energy deposited on the selected polyatob z mic ions during injection, butylbenzene molecular ions were chosen as a model for internal energy measurement. The e †ects of the r.f. injection level and helium pressure on the injected ion fragmentation were studied. The M'ĩ ons were only observed through a narrow injection window. At low values, only low critical energy m/z 92 q z q z ions were detected, while the higher critical energy m/z 91 ions were observed at higher values.


📜 SIMILAR VOLUMES


Origin of mass shifts in the quadrupole
✍ James Patrick Murphy III; Richard A. Yost 📂 Article 📅 2000 🏛 John Wiley and Sons 🌐 English ⚖ 48 KB 👁 2 views

A novel hybrid tandem mass analyzer, coupling a quadrupole ion trap with a quadrupole mass filter, has been constructed to permit mass analysis of ions ejected from the ion trap. The initial application of this instrument is the investigation of the origin of mass shifts in the ion trap due to ion f