Influence of scale prevention on corrosion of heat-transfer tube

โœ Scribed by J. Sakuma; T. Takagi; S. Yamada; Y. Kibe


Publisher
Elsevier Science
Year
1974
Tongue
English
Weight
380 KB
Volume
14
Category
Article
ISSN
0011-9164

No coin nor oath required. For personal study only.

โœฆ Synopsis


The pH-control method usually used in the latest distillation plants has been found unsuitable because of its corrosiveness.

In the cases of the pH-control tests, the corrosion rate of a heat-transfer tube was three times or more than that of the untreated operation.

An intermittent acid treatment developed recently in our laboratory was also tested. and resulted in the same amount of corrosion as the pHsontro1 method. These results were electrochemically studied tracing the change in the polarization curves of the tube. As a result of these experiments. it was concluded that an extremely low oxygen concentration under 3 ppb must be required to keep down the corrosion rate when using the acid treatments. SYMBOLS A -Heat-transfer area, rn' CP -Heat capacity of brine, kcal/kg "C F -Flow rate of brine, kgjhr 0 -F-C, (t2 -r ,). kcal/hr t1 -Brine temperature at the inlet, 'C I2 -Brine tempenture at the outlet.