Influence of end plate splices on the load carrying capacity of columns
โ Scribed by H.H. Snijder; J.C.D. Hoenderkamp
- Publisher
- Elsevier Science
- Year
- 2008
- Tongue
- English
- Weight
- 919 KB
- Volume
- 64
- Category
- Article
- ISSN
- 0143-974X
No coin nor oath required. For personal study only.
โฆ Synopsis
A column splice is part of the column and therefore must be designed for second order bending moments and shear forces in addition to the axial force. In this paper strength and stiffness requirements for column splices are derived on the basis of column stability considerations. A strength requirement for the column splice is suggested based on an imperfect column. A stiffness requirement is suggested by allowing a 5% reduction in the Euler buckling load of the column. In order to test the suggested design requirements for column splices, full scale experimental tests on spliced columns were carried out. Three different column splices were investigated. Columns without splices were tested for reference purposes. All tests were performed three times. It has been found that splices can have a negative influence on the load carrying capacity of slender columns.
๐ SIMILAR VOLUMES
## Ah&act-In this paper theoretical and experimental investigations have been carried out to determine the effect of an asymmetrical V-shaped notch on the load carrying capacity of eccentrically loaded columns. The depth of the notch was kept constant whereas the notch angle, notch root radius; ec