𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Influence of bone quality on the strength of internal and external fixation of tibial plateau fractures

✍ Scribed by Ahmad M. Ali; Michael Saleh; Richard Eastell; Carlos A. Wigderowitz; Alan S. Rigby; Lang Yang


Publisher
Elsevier Science
Year
2006
Tongue
English
Weight
192 KB
Volume
24
Category
Article
ISSN
0736-0266

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

We studied the influence of different parameters of bone quality on the fixation strength of bicondylar tibial plateau fractures and examined the relationship between these parameters. Bone quality was measured in the plateau of 16 cadaveric tibias using three modalities: dual‐energy X‐ray absorptiometry (DXA), peripheral quantitative computer tomography (pQCT), and spectral analysis of digitized radiographs (SADR). The tibias were divided into two groups by the median bone mineral density (BMD) and randomized to receive either dual plating or external fixator for the stabilization of a standardized bicondylar tibial fracture. The fixed fractures were subjected to axial compression until failure. DXA BMD correlated most significantly with the failure load (r β‰₯ 0.79, p < 0.001), followed by the pQCT parameters of cancellous bone (0.52 β‰₯ r β‰₯ 0.73, p < 0.01). Similar strong correlations were also evident in both fixation methods. For parameters derived from SADR, only those including both longitudinal and transverse trabecular orientations had modest correlation with the fixation strength (0.53 β‰₯ r β‰₯ 0.71, p < 0.01). The failure loads of the two fixation techniques were not significantly different (mean ± SD = 3522 ± 1386 N and 3710 ± 1356 N, respectively, p = 0.78). However, BMD in the dual‐plating group influenced the failure load significantly (p = 0.03), whereas in the external fixation group this was less evident (p = 0.100). The majority of bone quality parameters that correlated with fixation strength were also strongly correlated with each other, particularly the BMDs measured by DXA and pQCT. This is the first study that relates fixation strength of bicondylar tibial plateau fractures to bone quality assessed at the same anatomical site. BMD around the fracture site had the best correlation with the failure load regardless of the fixation technique. The two fixation methods tested performed equally well, and the choice between them depends on the soft tissue condition and surgeon preference. Β© 2006 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 24:2080–2086, 2006


πŸ“œ SIMILAR VOLUMES


Histomorphometric study on high-strength
✍ Furukawa, Taizo ;Matsusue, Yoshitaka ;Yasunaga, Tsunoru ;Nakagawa, Yasuaki ;Okad πŸ“‚ Article πŸ“… 2000 πŸ› John Wiley and Sons 🌐 English βš– 798 KB

The purpose of this study was to investigate the bone-implant interface of high-strength hydroxyapatite (HA)/poly(L-lactide) (PLLA) composite rods. As reinforcing particles, two types of HA particles-calcined HA (c-HA) and uncalcined HA (u-HA)-were applied to allow comparison of their suitability as

The effect of the association of near in
✍ Cibele B. Lopes; Marcos T. T. Pacheco; Landulfo Silveira Jr.; Maria Cristina T. πŸ“‚ Article πŸ“… 2010 πŸ› John Wiley and Sons 🌐 English βš– 188 KB πŸ‘ 1 views

## Abstract Fractures have different etiology and treatment and may be associated or not to bone losses. Laser light has been shown to improve bone healing. We aimed to assess, through Raman spectroscopy, the level of CHA (∼958 cm^βˆ’1^) on complete fractures animals treated with IRF treated or not w

Influence of internal fixator flexibilit
✍ Roland Steck; Masaki Ueno; Laura Gregory; Noortje. Rijken; Martin E. Wullschlege πŸ“‚ Article πŸ“… 2011 πŸ› Elsevier Science 🌐 English βš– 620 KB

## Abstract Mechanically well‐defined stabilization systems have only recently become available, providing standardized conditions for studying the role of the mechanical environment on mouse bone fracture healing. The aim of this study was to characterize the time course of strength recovery and c

Long-term study of high-strength hydroxy
✍ Ishii, Shinsuke ;Tamura, Jiro ;Furukawa, Taizo ;Nakamura, Takashi ;Matsusue, Yos πŸ“‚ Article πŸ“… 2003 πŸ› John Wiley and Sons 🌐 English βš– 394 KB

## Abstract Biodegradation of hydroxyapatite (HA)/poly(L‐lactide)(PLLA) composite bone implant rods was studied with the use of two types of HA particles as reinforcing fillers: uncalcined HA (u‐HA) or calcined HA (c‐HA). Composite rods of u‐HA/PLLA and c‐HA/PLLA containing 30 or 40% (w/w) HA were

The influence of femoral internal and ex
✍ Thor F. Besier; Garry E. Gold; Scott L. Delp; Michael Fredericson; Gary S. Beaup πŸ“‚ Article πŸ“… 2008 πŸ› Elsevier Science 🌐 English βš– 236 KB

## Abstract Internal and external rotation of the femur plays an important role in defining the orientation of the patellofemoral joint, influencing contact areas, pressures, and cartilage stress distributions. The purpose of this study was to determine the influence of femoral internal and externa