๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

In vivo stability and biocompatibility of implanted calcium alginate disks

โœ Scribed by Elizabeth A. Nunamaker; Erin K. Purcell; Daryl R. Kipke


Publisher
John Wiley and Sons
Year
2007
Tongue
English
Weight
403 KB
Volume
83A
Category
Article
ISSN
1549-3296

No coin nor oath required. For personal study only.

โœฆ Synopsis


Abstract

Alginate is a commonly used biomedical hydrogel whose in vivo degradation behavior is only beginning to be understood. The use of alginate in the central nervous system is gaining popularity as an electrode coating, cell encapsulation matrix, and for duraplasty. However, it is necessary to understand how the hydrogel will behave in vivo to aid in the development of alginate for use as a neural interface material. The goal of the current study was to compare the rheological behavior of explanted alginate disks and the inflammatory response to subcutaneously implanted alginate hydrogels over a 3โ€month period. Specifically, the effects due to (1) in situ gelling, (2) diffusion gelling, and (3) use of a polyโ€lโ€lysine (PLL) coating were investigated. While all samples' complex moduli decreased 80% in the first day, in situ gelled alginate was more stable for the first week of implantation. The PLL coating offered some stability increases for diffusion gelled alginate, but the stability in both conditions remained significantly lower than that in in situ gelled alginate. There were no differences in biocompatibility that clearly suggested one gelation method over another. These results indicate that in situ gelation is the preferred method in neural interface applications where stability is the primary concern. ยฉ 2007 Wiley Periodicals, Inc. J Biomed Mater Res 2007


๐Ÿ“œ SIMILAR VOLUMES


In vivo biocompatibility and mechanical
โœ Zhang, X. S. ;Revell, P. A. ;Evans, S. L. ;Tuke, M. A. ;Gregson, P. J. ๐Ÿ“‚ Article ๐Ÿ“… 1999 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 499 KB ๐Ÿ‘ 1 views

Two epoxy materials with or without adhesively bonded hydroxyapatite (HA) coatings were studied for their biocompatibility and mechanical pushout strength using in vivo implantation in the rabbit lower femur for a duration of 10 days to 6 months. Both were two-part epoxies cured at room temperature

Development, implantation, in vivo eluti
โœ Nathan R.F. Beeley; Jay M. Stewart; Ryotaro Tano; Laurie R. Lawin; Ralph A. Chap ๐Ÿ“‚ Article ๐Ÿ“… 2006 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 381 KB ๐Ÿ‘ 2 views

## Abstract A biocompatible, sustainedโ€release subretinal drugโ€delivery platform was developed to overcome the therapeutic accessibility limitations of current retinal disease treatments. The prototype implants were fabricated by coating nitinol, poly(methyl methacrylate) or chromic gut core filame

An in vivo evaluation of the biocompatib
โœ P. Schlegel; J. S. Hayes; V. M. Frauchiger; B. Gasser; R. Wieling; M. Textor; R. ๐Ÿ“‚ Article ๐Ÿ“… 2008 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 374 KB ๐Ÿ‘ 1 views

## Abstract Implant loosening is an unresolved complication associated with prosthetics. Previous studies report improved osseointegration with hydroxyapatite (HA) or triโ€calcium phosphate coatings. Unfortunately, the brittleness and low strength of these coatings in adhesion to the implant or inte

A novel porous collagen scaffold around
โœ Young Min Ju; Bazhang Yu; Thomas J. Koob; Yvonne Moussy; Francis Moussy ๐Ÿ“‚ Article ๐Ÿ“… 2008 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 486 KB ๐Ÿ‘ 1 views

## Abstract A new 3D porous and biostable collagen scaffold has been developed to improve the biocompatibility of implantable glucose sensors by minimizing tissue reactions while stimulating angiogenesis around the sensors. The novel collagen scaffold was crosslinked using nordihydroguaiaretic acid