## Abstract Kinetics of mRNA expression following a single loading event was measured using an in vivo rat tail model. Animals were instrumented and loaded in compression for 1.5 h at 1 MPa and 1 Hz. Real‐time RT‐PCR was used to measure mRNA levels 0, 8, 24 and 72 h after mechanical stimulation for
In vivo remodeling of intervertebral discs in response to short- and long-term dynamic compression
✍ Scribed by Karin Wuertz; Karolyn Godburn; Jeffrey J. MacLean; Ana Barbir; Justin Stinnett Donnelly; Peter J. Roughley; Mauro Alini; James C. Iatridis
- Publisher
- Elsevier Science
- Year
- 2009
- Tongue
- English
- Weight
- 303 KB
- Volume
- 27
- Category
- Article
- ISSN
- 0736-0266
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
This study evaluated how dynamic compression induced changes in gene expression, tissue composition, and structural properties of the intervertebral disc using a rat tail model. We hypothesized that daily exposure to dynamic compression for short durations would result in anabolic remodeling with increased matrix protein expression and proteoglycan content, and that increased daily load exposure time and experiment duration would retain these changes but also accumulate changes representative of mild degeneration. Sprague‐Dawley rats (n = 100) were instrumented with an Ilizarov‐type device and divided into three dynamic compression (2 week–1.5 h/day, 2 week–8 h/day, 8 week–8 h/day at 1 MPa and 1 Hz) and two sham (2 week, 8 week) groups. Dynamic compression resulted in anabolic remodeling with increased matrix mRNA expression, minimal changes in catabolic genes or disc structure and stiffness, and increased glysosaminoglycans (GAG) content in the nucleus pulposus. Some accumulation of mild degeneration with 8 week–8 h included loss of annulus fibrosus GAG and disc height although 8‐week shams also had loss of disc height, water content, and minor structural alterations. We conclude that dynamic compression is consistent with a notion of “healthy” loading that is able to maintain or promote matrix biosynthesis without substantially disrupting disc structural integrity. A slow accumulation of changes similar to human disc degeneration occurred when dynamic compression was applied for excessive durations, but this degenerative shift was mild when compared to static compression, bending, or other interventions that create greater structural disruption. © 2009 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res
📜 SIMILAR VOLUMES
## Abstract The goal of this study was to characterize the anabolic and catabolic mRNA response of the disc to dynamic loading to determine if variations in the magnitude and/or frequency of loading could elicit different cellular responses. Sixty‐eight Wistar rats were instrumented with an Ilizaro
## Abstract Long term __in vivo__ degradation, and tissue response to, cylindrical elastomers made of photo‐cross‐linked star‐poly(ε‐caprolactone‐__co__‐D,L‐lactide) triacrylate were investigated through subcutaneous implantation in rats. The elastomers were prepared via UV initiated crosslinking o