𝔖 Bobbio Scriptorium
✦   LIBER   ✦

In vivo evaluation of a novel electrically conductive polypyrrole/poly(D,L-lactide) composite and polypyrrole-coated poly(D,L-lactide-co-glycolide) membranes

✍ Scribed by Wang, Zhaoxu ;Roberge, Christophe ;Dao, L� H. ;Wan, Ying ;Shi, Guixin ;Rouabhia, Mahmoud ;Guidoin, Robert ;Zhang, Ze


Publisher
John Wiley and Sons
Year
2004
Tongue
English
Weight
820 KB
Volume
70A
Category
Article
ISSN
0021-9304

No coin nor oath required. For personal study only.

✦ Synopsis


This study evaluated the in vivo biocompatibility and biodegradation behavior of a novel polypyrrole (PPy)/poly(D,L-lactide) (PDLLA) composite and PPy-coated poly(D,L-lactide-co-glycolide) membranes. Test membranes were implanted subcutaneously in rats for 3-120 days. The biocompatibility was assessed by quantifying the alkaline and acid phosphatase secretion, the immunohistochemical staining of the ED-2-positive macrophages, and the histology at the tissue/material interface. The degradation was investigated using scanning electron microscopy. Pure PDLLA and poly(D,L-lactide-co-glycolide) membranes were used as references, whereas expanded polytetrafluoroethylene and a commercial styrene-butadiene rubber were used as controls. The enzyme activity of the PPy-containing specimens was shown to be similar to that of the references. The histological findings were consistent with the enzymatic results, showing a mild-to-moderate acute inflammation followed by a resolution of the inflammatory response with a decrease in inflammatory cells for each biodegradable membrane. The tissue reactions to the PPy, which was either in the form of nanoparticles or surface coating, were comparable to the response to the neighboring biodegradable materials. Elevated ED-2-positive macrophage populations appeared as early as day 3 in the loose connective tissue surrounding the implants. The density of these populations was related to the degree of inflammation. Scanning electron microscopy showed that the degradation of the PPy/PDLLA composite was not affected by the presence of PPy.


📜 SIMILAR VOLUMES


Ketotifen-loaded microspheres prepared b
✍ Sandra Guerrero; Enriqueta Muñíz; César Teijón; Rosa Olmo; José M. Teijón; M. Do 📂 Article 📅 2008 🏛 John Wiley and Sons 🌐 English ⚖ 629 KB

Ketotifen (KT) was encapsulated into poly(D,L-lactide) (PLA) and poly(D,Llactide-co-glycolide) (PLGA 50/50) by spray-drying to investigate the use of biodegradable drug-loaded microspheres as delivery systems in the intraperitoneal cavity. Ketotifen stability was evaluated by HPLC, and degradation w

A biodegradable electrical bioconductor
✍ Wang, Zhaoxu ;Roberge, Christophe ;Wan, Ying ;Dao, L� H. ;Guidoin, Robert ;Zhang 📂 Article 📅 2003 🏛 John Wiley and Sons 🌐 English ⚖ 268 KB

## Abstract The electrical stability of a novel polypyrrole (PPy)/poly(D,L‐lactide) (PDLLA) composite was studied __in vitro__ and compared with that of PPy‐coated polyester fabrics. Specimens were incubated in Ringer's solution at 37°C for up to 8 weeks with or without the circulation of DC curren

In vitro and in vivo analysis of macropo
✍ Richard M. Day; Véronique Maquet; Aldo R. Boccaccini; Robert Jérôme; Alastair Fo 📂 Article 📅 2005 🏛 John Wiley and Sons 🌐 English ⚖ 294 KB 👁 1 views

## Abstract Recent studies have demonstrated the angiogenic potential of 45S5 Bioglass®. However, it is not known whether the angiogenic properties of Bioglass® remain when the bioactive glass particles are incorporated into polymer composites. The objectives of the current study were to investigat