## Abstract The ideal biomaterial for the repair of bone defects is expected to have good mechanical properties, be fabricated easily into a desired shape, support cell attachment, allow controlled release of bioactive factors to induce bone formation, and biodegrade into nontoxic products to permi
In vivo degradation of a poly(propylene fumarate)/?-tricalcium phosphate injectable composite scaffold
โ Scribed by Peter, Susan J. ;Miller, Seth T. ;Zhu, Guoming ;Yasko, Alan W. ;Mikos, Antonios G.
- Publisher
- John Wiley and Sons
- Year
- 1998
- Tongue
- English
- Weight
- 267 KB
- Volume
- 41
- Category
- Article
- ISSN
- 0021-9304
No coin nor oath required. For personal study only.
โฆ Synopsis
This study was designed to investigate the in vivo biodegration and biocompatibility of a poly(propylene fumarate) (PPF)-based orthopedic biomaterial. The effects of varying the PPF to N-vinyl pyrrolidinone ratio and PPF to โค-tricalcium phosphate content were studied. The composite mechanical properties and local tissue interactions were analyzed over 12 weeks. An initial increase in both compressive modulus and strength was seen for composite formulations that incorporated โค-tricalcium phosphate. The samples incorporating a higher PPF to N-vinyl pyrrolidinone ratio reached a maximal compressive strength of 7.7 MPa and a maximal compressive modulus of 191.4 MPa at 3 weeks. The lower PPF to N-vinyl pyrrolidinone ratio samples gained a maximum compressive strength of 7.5 MPa initially and a compressive modulus of 134.0 MPa at 1 week. At 6 weeks, all samples for formulations incorporating โค-tricalcium phosphate crumbled upon removal and were not mechanically tested. Samples that did not incorporate โค-tricalcium phosphate were very weak and insufficient for bone replacement at the 4-day time point and beyond. Tissue interactions resulted in a mild inflammatory response at the initial time points and mature fibrous encapsulation by 12 weeks.
๐ SIMILAR VOLUMES
We have developed a biodegradable particulate composite bone cement consisting of a poly(propylene glycolfumarate)-(methylmethacrylate) matrix mixed with calcium carbonate and tricalcium phosphate particulates. Previous ex vivo studies suggest that this system provides sufficient strength for a numb
The degradation of poly(propylene fumarate-coethylene glycol) hydrogels was examined in vitro in phosphate-buffered saline at pH 7.4 and in vivo in a subcutaneous rat model. These hydrogels have potential application as biodegradable, injectable cardiovascular stents, and, as such, their mass loss,