## Abstract The aim of this study was to evaluate the safety and tissue compatibility of an injectable biodegradable poly(esterβanhydride) copolymer of ricinoleic acid (RA) and sebacic acid (SA) in rats. The absorbable biomaterial containing 70% w/w of RA and 30% w/w of SA [P(SAβRA) 3:7] was implan
In vivo biodegradability and biocompatibility evaluation of novel alanine ester based polyphosphazenes in a rat model
β Scribed by Swaminathan Sethuraman; Lakshmi S. Nair; Saadiq El-Amin; Robert Farrar; My-Tien N. Nguyen; Anurima Singh; Harry R. Allcock; Yaser E. Greish; Paul W. Brown; Cato T. Laurencin
- Publisher
- John Wiley and Sons
- Year
- 2006
- Tongue
- English
- Weight
- 904 KB
- Volume
- 77A
- Category
- Article
- ISSN
- 1549-3296
No coin nor oath required. For personal study only.
β¦ Synopsis
Abstract
Amino acid ester substituted polyphosphazenes are attractive candidates for various biomedical applications because of their biocompatibility, controllable hydrolytic degradation rates, and nontoxic degradation products. In this study, the biocompatibility of three Lβalanine ethyl ester functionalized polyphosphazenes was evaluated in a subcutaneous rat model. The polymers used in the study were poly[bis(ethylalanato)phosphazene] (PNEA), poly[(50% ethylalanato) (50% methylphenoxy) phosphazene] (PNEA~50~mPh~50~), and poly[(50% ethylalanato)(50% phenyl phenoxy) phosphazene] (PNEA~50~PhPh~50~). Polymer disks of diameter 7.5 mm were prepared by a solvent evaporation technique and were implanted subcutaneously in rats. After 2, 4, and 12 weeks, the polymer along with the surrounding tissues were excised, prepared, and viewed by light microscopy to evaluate the tissue responses of the implanted polymers. The tissue responses were classified as minimal, mild, or moderate, based on a biocompatibility scheme developed in our laboratory. Minimal inflammation was characterized by the presence of few neutrophils, erythrocytes, and lymphocytes; mild response was characterized by the predominant presence of macrophages, fibroblasts, or giant cells; and moderate inflammation was characterized by the abundance of macrophages, giant cells, and by the presence of tissue exudates. The in vivo degradation profiles of the polymers at various time points were evaluated by gel permeation chromatography (GPC). PNEA and PNEA~50~mPh~50~ matrices elicited varying levels of tissue responses during the 12βweek implantation period. At 2 weeks both polymers evoked a moderate response, and by 12 weeks the response was found to be mild. However, PNEA~50~PhPh~50~ elicited a mild response at the end of 2 weeks and demonstrated a further decreased inflammatory response after12 weeks. The in vivo degradation of the polymers was followed by determining the molecular weights of the explanted polymer disks. PNEA and PNEA~50~mPh~50~ disks showed significant decrease in molecular weight after 2 weeks of implantation. The molecular weights of PNEA and PNEA~50~mPh~50~ residues could not be determined by GPC after 12 weeks of implantation because of almost complete degradation. On the other hand the in vivo degradation of PNEA~50~PhPh~50~ was found to be slow, with a 63% loss in molecular weight in 12 weeks. Furthermore, this polymer maintained its shape and structure during the entire study. Thus, these polymers demonstrated excellent tissue compatibility and in vivo biodegradability and can be potential candidates for various biomedical applications. Β© 2006 Wiley Periodicals, Inc. J Biomed Mater Res, 2006
π SIMILAR VOLUMES
## Abstract Aliphatic segmented poly(ester amide)s, comprising a crystallizable amide phase and a flexible amorphous ester phase, were investigated for potential use in biomedical applications. By varying the amide content and the type of crystallizable amide segments, the polymer's thermal and mec
## Abstract We recently developed a novel biological glue from tartaric acid derivative (TAD) with two active ester groups and human serum albumin (HSA), named TADβA. In this study, __in vivo__ experiments were performed to investigate clinical applicability of TADβA. TAD was prepared by reacting c
## Abstract The ability of an albuminβbased hydrogel sealant (ABHS) to prevent air leakage through the suture line after pulmonary surgery was evaluated by comparison with that of a fibrin glue (FG). As an airβleak model, a rat lung was used in which a standard incision was made and the burst press