✦ Synopsis


A one-dimensional time-of-flight MR sequence, having a total acquisition time of approximately 60 ms, has been employed to determine flow-wave propagation velocities for pulsatile flow in compliant latex tubes. The results were compared with those of two independent methods and were found to be in good agreement. An extension of the same MR method was used to test the validity of the "water-hammer" relationship as a means to assess pulse pressure. Very good agreement was found with direct manometric determinations of pulse pressure.


πŸ“œ SIMILAR VOLUMES


Rapid measurement of aortic wave velocit
✍ Kenneth A. Kraft; Vitalii V. Itskovich; Ding-Yu Fei πŸ“‚ Article πŸ“… 2001 πŸ› John Wiley and Sons 🌐 English βš– 237 KB

A 1D MR sequence has been developed for determining aortic flow wave velocity (WV), a metric of arterial compliance, within a single cardiac cycle. Studies were carried out on the thoracic aortas of 10 normal volunteers. Correlative WV data were also acquired from each subject using a conventional p

Rapid measurement of pulse wave velocity
✍ Xianzhi Shao; Ding-yu Fei; Kenneth A. Kraft πŸ“‚ Article πŸ“… 2004 πŸ› John Wiley and Sons 🌐 English βš– 260 KB

## Abstract A MR method is presented for measuring pulse wave velocity (PWV) and its application to assessing stiffness in the human thoracic aorta. This one‐dimensional (1D) flow displacement method applies a single RF comb excitation to the vessel, followed by an oscillating frequency encoding gr

In vitro validation of MR measurements o
✍ Maja Stevanov; Joseph Baruthio; Daniel Gounot; Daniel Grucker πŸ“‚ Article πŸ“… 2001 πŸ› John Wiley and Sons 🌐 English βš– 139 KB

## Abstract A magnetic resonance imaging projective velocity encoding sequence was used to determine the pulse‐wave velocity in an artery model. To this end, a well‐defined flow phantom simulating flow propagation in large arteries was used. In order to validate the measurement method in the presen

Pulse-wave velocity measured in one hear
✍ Christopher K. Macgowan; R. Mark Henkelman; Michael L. Wood πŸ“‚ Article πŸ“… 2002 πŸ› John Wiley and Sons 🌐 English βš– 232 KB

A noninvasive method for measuring the aortic pulse-wave velocity (PWV) in a single heartbeat is introduced. The method sinusoidally tags a column of blood within the vessel, and rapidly acquires a series of 1D projections of the tags as they move (in practice, 64 projections at 4-ms intervals). Fro

Measurement of aortic arch pulse wave ve
✍ Anas Dogui; Alban Redheuil; Muriel Lefort; Alain DeCesare; Nadjia Kachenoura; Al πŸ“‚ Article πŸ“… 2011 πŸ› John Wiley and Sons 🌐 English βš– 215 KB

## Abstract ## Purpose: To investigate the efficiency of a new method (TT‐Upslope) for transit time (Ξ”t) estimation from cardiovascular MR (CMR) velocity curves. ## Materials and Methods: Fifty healthy volunteers (40 Β± 15 years) underwent applanation tonometry to estimate carotid–femoral pulse w