𝔖 Bobbio Scriptorium
✦   LIBER   ✦

In vitro stability predictions for the bone/hydroxyapatite composite system

✍ Scribed by Oppermann, Dean A. ;Crimp, Melissa J. ;Bement, David M.


Publisher
John Wiley and Sons
Year
1998
Tongue
English
Weight
162 KB
Volume
42
Category
Article
ISSN
0021-9304

No coin nor oath required. For personal study only.

✦ Synopsis


Electroacoustic measurements of the zeta (zeta) potential as a function of pH were collected and used to probe the nature of the ionic contributions to the bond formed between synthetic hydroxyapatite (HA) and bone. HA powder and wet bone powder were dispersed into an electrolyte solution comprised of physiologic saline (0.154M NaCl), electroacoustic measurements collected, and the zeta potential calculated as a function of pH. The zeta potential and particle size then were used to calculate the stability of the composite dispersion, where stability is the ability of a particulate suspension to remain unagglomerated. The stability was used to predict the homo- (HA to HA and bone to bone) versus heterocoagulation (HA to bone) behaviors for the HA/bone system. Although single component bone and HA demonstrated stability against agglomeration, the HA/bone interaction was determined to be unstable for all pH levels tested, including pH 7.4, the normal in vivo pH. These results establish one factor responsible for the observed physicochemical bonding between bone and HA noted by many in the orthopedic community.


πŸ“œ SIMILAR VOLUMES


Poly-Ο΅-caprolactone/hydroxyapatite compo
✍ F. Causa; P. A. Netti; L. Ambrosio; G. Ciapetti; N. Baldini; S. Pagani; D. Marti πŸ“‚ Article πŸ“… 2006 πŸ› John Wiley and Sons 🌐 English βš– 967 KB

## Abstract Polycaprolactone (PCL), a semicrystalline linear resorbable aliphatic polyester, is a good candidate as a scaffold for bone tissue engineering, due to its biocompatibility and biodegradability. However, the poor mechanical properties of PCL impair its use as scaffold for hard tissue reg

Fabrication, characterization, and in vi
✍ Qing Lv; Lakshmi Nair; Cato T. Laurencin πŸ“‚ Article πŸ“… 2009 πŸ› John Wiley and Sons 🌐 English βš– 680 KB

## Abstract Dynamic flow culture bioreactor systems have been shown to enhance __in vitro__ bone tissue formation by facilitating mass transfer and providing mechanical stimulation. Our laboratory has developed a biodegradable poly (lactic acid glycolic acid) (PLAGA) mixed scaffold consisting of li

Long-term study of high-strength hydroxy
✍ Ishii, Shinsuke ;Tamura, Jiro ;Furukawa, Taizo ;Nakamura, Takashi ;Matsusue, Yos πŸ“‚ Article πŸ“… 2003 πŸ› John Wiley and Sons 🌐 English βš– 394 KB

## Abstract Biodegradation of hydroxyapatite (HA)/poly(L‐lactide)(PLLA) composite bone implant rods was studied with the use of two types of HA particles as reinforcing fillers: uncalcined HA (u‐HA) or calcined HA (c‐HA). Composite rods of u‐HA/PLLA and c‐HA/PLLA containing 30 or 40% (w/w) HA were