## Abstract ## Background. After total laryngectomy and voice rehabilitation using a tracheoesophageal shunt valve, patients often have valveโrelated complications such as leakage. To solve these problems, a tracheoesophageal tissue connector (TEโTC) was devised to serve as an interface between th
In vitro leakage susceptibility of tracheoesophageal shunt prostheses in the absence and presence of a biofilm
โ Scribed by Janine J. H. Oosterhof; Henny C. van der Mei; Henk J. Busscher; Rolien H. Free; Hans J. Kaper; Ranny van Weissenbruch; Frans W. J. Albers
- Publisher
- John Wiley and Sons
- Year
- 2005
- Tongue
- English
- Weight
- 192 KB
- Volume
- 73B
- Category
- Article
- ISSN
- 1552-4973
No coin nor oath required. For personal study only.
โฆ Synopsis
Abstract
Although leakage through a tracheoesophageal shunt prosthesis is the main cause of prosthesis failure in a laryngectomy patient, this has never been the subject of in vitro evaluation. The aim of this study was to compare three commercially available voice prostheses by comparison of their in vitro leakage patterns, in absence or presence of a biofilm. To compare in vitro leakage patterns, a model comprised of an artificial throat equipped with a single prosthesis coupled to a water reservoir was developed. By varying the height of the water reservoir, different pressures on the voice prosthesis can be obtained. Both in absence and presence of a biofilm, the Blom Singer voice prosthesis demonstrated the lowest leakage, followed by Groningen Low Resistance. The Provoxยฎ2 showed significantly the most leakage, however, in presence of a biofilm the leakage of the Provoxยฎ2 significantly decreased. Regular airflow during biofilm formation significantly increased leakage through the Provoxยฎ2. Out of 746 clinical replacements, Provoxยฎ2 showed 76% and Groningen Low Resistance 57% replacements due to leakage. The model used in this study showed significant differences in leakage of the three types of voice prostheses used. Leakage occurred more readily through Provoxยฎ2 than through Groningen Low Resistance and Blom Singer prostheses, which is in line with clinical observations and enforces the model. ยฉ 2005 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 73B: 23โ28, 2005
๐ SIMILAR VOLUMES
2-Propyl radicals have been generated from the photolysis of solutions OF 2,2-azopropane and 2,4-dirnethyl-?-pentanone in decane in a glass and a metal cell. The time course of their reactions in the presence and absence of oxygen has been monitored between 323 and ## 373 K The primary process inv
## Abstract Intrinsic viscosities were determined for solutions of CMG in pure water and 0.9 wt.โ% aqueous NaCl. To avoid the 0/0โtype extrapolation typical for Huggins plots, a new procedure was used. For CMG and pure water, this requires only two adjustable parameters: the specific hydrodynamic v