This study investigated the impact of a combination of axial compressive and anterior-posterior tibial loads on the in situ forces in the anterior cruciate ligament. An axial compressive load is believed to contribute to increased stability of the knee joint; however, its effect on in situ forces in
In situ forces in the anterior cruciate ligament and its bundles in response to anterior tibial loads
✍ Scribed by Masataka Sakane; Ross J. Fox; Savio L-Y. Woo Glen; A. Livesay; Guoan Li; Freddie H. Fu
- Publisher
- Elsevier Science
- Year
- 1997
- Tongue
- English
- Weight
- 943 KB
- Volume
- 15
- Category
- Article
- ISSN
- 0736-0266
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
The anterior cruciate ligament has a complex fiber anatomy and is not considered to be a uniform structure. Current anterior cruciate ligament reconstructions succeed in stabilizing the knee, but they neither fully restore normal knee kinematics nor reproduce normal ligament, function. To improve the outcome of the reconstruction, it may be necessary to reproduce the complex function of the intact anterior cruciate ligament in the replacement graft. We examined the in situ forces in nine human anterior cruciate ligaments as well as the force distribution between the anteromedial and posterolateral bundles of the ligament in response to applied anterioi tibial loads ranging from 22 to 110 N at knee flexion angles of 0–90°. The analysis was performed using a robotic manipulator in conjunction with a universal force‐moment sensor. The in situ forces were determined with no device attached to the ligament, while the knee was permitted to move freely in response to the applied loads. We found that the in situ forces in the anterior cruciate ligament ranged from 12.8 ± 7.3 N under 22 N of anterior tibial load applied at 90° of knee flexion to 110.6 ± 14.8 N under 110 N of applied load at 15° of flexion. The magnitude of the in situ force in the posterolateral bundle was larger than that in the anteromedial bundle at knee flexion angles between 0 and 45°, reaching a maximum of 75.2 ± 18.3 N at 15° of knee flexion under an anterior tibial load of 110 N. The magnitude of the in situ force in the posterolateral bundle was significantly affected by knee flexion angle and anterior tibial load in a fashion remarkably similar to that seen in the anterior cruciate ligament. The magnitude of the in situ force in the anteromedial bundle, in contrast, remained relatively constant, not changing with flexion angle. Significant differences in the direction of the in situ force between the anteromedial bundle and the posterolateral bundle were found only at flexion angles of 0 and 60° and only under applied anterior tibial loads greater than 66 N. We have demonstrated the nonuniformity of the anterior cruciate ligament under unconstrained anterior tibial loads. Our data further suggest that in order for the anterior cruciate ligament replacement graft to reproduce the in situ forces of the normal anterior cruciate ligament, reconstruction techniques should take into account the role of the posterolateral bundle in addition to that of the anteromedial bundle.
📜 SIMILAR VOLUMES
## Abstract A noncontact, kinematic method was used to determine the lengths and in situ loads borne by portions of the human anterior cruciate ligament (ACL) by the combination of kinematic data from the intact knee and load‐length curves of the isolated ACL. Specimens from knees of cadavers of yo
## Abstract Strain within the anteromedial bundle (AMB) of the anterior cruciate ligament (ACL) was measured in 13 human knee specimens in order to determine the combination of external loads most likely to cause injury. Using a load application system that allowed 5 __df__ with the flexion angle b
## Abstract The objectives of this study were to determine the effects of hamstrings and quadriceps muscle loads on knee kinematics and __in situ__ forces in the posterior cruciate ligament of the knee and to evaluate how the effects of these muscle loads change with knee flexion. Nine human cadave
## Abstract Cruciate ligament tensions were predicted for anteroposterior (AP) tibial translation at 20°, 30°, 80°, and 90° of knee flexion based on in vitro measurements from six cadaver knees. A three‐dimensional trigonometric equation was derived to calculate ligament tension as functions of AP
## Abstract The function of the anterior cruciate ligament was investigated for different conditions of kinematic constraint placed on the intact knee using a six‐degree‐of‐freedom robotic manipulator combined with a universal force‐moment sensor. To do this, the __in situ__ forces and force distri