𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Improving the temporal resolution of functional MR imaging using keyhole techniques

✍ Scribed by Jia-Hong Gao; Jinhu Xiong; Song Lai; E. Mark Haacke; Marty G. Woldorff; Jinqi Li; Peter T. Fox


Publisher
John Wiley and Sons
Year
1996
Tongue
English
Weight
797 KB
Volume
35
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Using a keyhole technique, it is shown that the data acquisition rate of gradient‐echo imaging for functional MRI (fMRI) studies can be increased substantially. The resulting enhancement of the temporal resolution of fMRIs was accomplished without modifying the hardware of a conventional MRI system. High spatial resolution fMRI images were first collected with conventional full k‐space acquisition and image reconstruction. Using the same data set, simulation reconstruction using the keyhole principle and zero‐padding were performed for comparison with the full k‐space reconstruction. No significant changes were found for fMRI images generated from the keyhole technique with a data sharing profile of 50% of the k‐space. As k‐space data sharing profiles increased to 75 and 87.5%, the keyhole fMRI images began to show only modest changes in activation intensity and area compared with the standard images. In contrast, zero‐padding fMRI images produced a significant disparity both in activation intensity and area relative to the truly high‐resolution fMRI images. The keyhole technique's ability to retain the intensity and area of fMRI information, while substantially reducing acquisition time, makes it a promising method for fMRI studies.


📜 SIMILAR VOLUMES


Time-resolved, high-resolution contrast-
✍ Katja A. Mende; Johannes M. Froehlich; Constantin von Weymarn; Romhild Hoogeveen 📂 Article 📅 2007 🏛 John Wiley and Sons 🌐 English ⚖ 513 KB

## Abstract ## Purpose To evaluate the use of a dynamic keyhole magnetic resonance angiography (MRA) sequence combined with sensitivity encoding (SENSE) for hemodialysis shunts, because surveillance with conventional contrast‐enhanced MRA (CE‐MRA) is limited by its low temporal resolution, resulti

Improving temporal resolution of pulmona
✍ Cornelius Brinegar; Sarah S. Schmitter; Nilesh N. Mistry; G. Allan Johnson; Zhi- 📂 Article 📅 2010 🏛 John Wiley and Sons 🌐 English ⚖ 688 KB

## Abstract Dynamic contrast‐enhanced MRI (or DCE‐MRI) is a useful tool for measuring blood flow and perfusion, and it has found use in the study of pulmonary perfusion in animal models. However, DCE‐MRI experiments are difficult in small animals such as rats. A recently developed method known as I

An investigation into the use of sensiti
✍ David J. Larkman; Nandita M. deSouza; Mark Bydder; Joseph V. Hajnal 📂 Article 📅 2001 🏛 John Wiley and Sons 🌐 English ⚖ 193 KB 👁 1 views

Gadolinium-enhanced dynamic magnetic resonance (MR) imaging is playing an increasingly important diagnostic role in patients with breast cancer. Because of the multi-focal nature of the disease, it is mandatory to cover all of both breasts, not only in the initial scan, but also at subsequent follow

Functional MR imaging using gradient-ech
✍ R. Todd Constable 📂 Article 📅 1995 🏛 John Wiley and Sons 🌐 English ⚖ 930 KB

## Abstract At 1.5 T, the field strength of most clinical MR imagers, gradient‐echo Imaging Is the primary imaging method for measuring brain activation, as such sequences are highly sensitive to changes in blood oxygenation or T2\* effects. Unfortunately, gradient‐echo sequences are also extremely