✦ Synopsis


A miniaturized time-of-flight (TOF) mass spectrometer utilizes an end-cap reflectron to achieve high kinetic energy focusing and improved mass resolution. However, the coaxial geometry gives rise to considerable losses in sensitivity resulting from reflected ion trajectories close to the center. These trajectories were modeled, using initial ion velocity distributions in the radial direction up to 300 m s -1 , and the portion of the active area of the detector that is utilized was evaluated experimentally using a variable diameter iris diaphragm. The sensitivity was improved by modification of the reflectron by tilting the end-cap electrode 4 β€’ and redirecting the ions to a portion of the detector active area. Sensitivity was then measured as 3 fmol of the peptide substance P.


πŸ“œ SIMILAR VOLUMES


A quadrupole ion trap/time-of-flight mas
✍ Doroshenko, Vladimir M.; Cotter, Robert J. πŸ“‚ Article πŸ“… 1998 πŸ› John Wiley and Sons 🌐 English βš– 470 KB πŸ‘ 1 views

A matrix-assisted laser desorption/ionization-quadrupole ion trap/reΓ‘ectron time-of-Γ‘ight (MALDI-QIT/reTOF) mass spectrometer design and its operation in both normal and tandem mass spectrometric modes are described. A parabolic reΓ‘ectron was found to be capable of providing mass resolution of 5000

Ion-neutral correlations from the dissoc
✍ Van Stipdonk, M. J.; Justes, D. R.; English, R. D.; Schweikert, E. A. πŸ“‚ Article πŸ“… 1999 πŸ› John Wiley and Sons 🌐 English βš– 146 KB πŸ‘ 1 views

A time-of-flight mass spectrometer with an electrostatic mirror was used to probe the composition and structure of polyatomic secondary ions via their metastable dissociation following the impact of MeV energy primary ions. The experimental approach combines event-by-event bombardment and detection

Simulation of External Ion Injection, Co
✍ Ling He; David M. Lubman πŸ“‚ Article πŸ“… 1997 πŸ› John Wiley and Sons 🌐 English βš– 370 KB πŸ‘ 1 views

In this work we have developed a PC-based simulation to study ion injection, cooling and extraction processes for multiple ions in an ion trap/reflectron time-of-flight (IT/reTOF) system. This simulation is based upon SIMION 6.0 with user written programs in which a 3D collision model is used to des

An Approach to the Design of Mass-correl
✍ S. V. Kovtoun πŸ“‚ Article πŸ“… 1997 πŸ› John Wiley and Sons 🌐 English βš– 111 KB πŸ‘ 1 views

An algorithm is suggested that allows the implementation of first order velocity (energy) focusing in a linear, single field, time-of-flight mass spectrometer (TOF/MS) over a broad mass range using a time-dependent mass-corrected extraction field. The interpolation formula for extraction field depen