𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Improvement of image resolution and quantitative accuracy in clinical Single Photon Emission Computed Tomography

✍ Scribed by F.J Beekman; C Kamphuis; M.A King; P.P van Rijk; M.A Viergever


Publisher
Elsevier Science
Year
2001
Tongue
English
Weight
652 KB
Volume
25
Category
Article
ISSN
0895-6111

No coin nor oath required. For personal study only.

✦ Synopsis


Clinical Single Photon Emission Computed Tomography (SPECT) is a scanning technique which acquires gamma-camera images ('projections') over a range of angles around a patient. These projections allow the reconstruction of cross sectional ('tomographic') images of the gamma-radiating pharmaceutical distribution in the patient, thus providing interesting information about the functioning of organs and tissues.SPECT images are seriously affected by a variety of image degrading processes. Restrictions on the amount of radio-pharmaceutical that can be administered to a patient cause noise in the projections and the limited spatial resolution of the gamma-camera results in blurring of the projections. In addition to these image degradations, the reconstruction of cross-sections is complicated by Compton scattering of gamma-photons in tissue, which causes attenuation of the photon flux received by the gamma-camera and causes improper detection of photons which have been scattered in tissue. This results in some additional blurring and loss of accuracy of the SPECT images in predicting activity concentrations. Tremendous efforts have been made to improve the quantitative accuracy and the spatial resolution of SPECT, and to reduce the noise in the reconstructed images. These efforts have resulted in corrective reconstruction algorithms, which are generally based on incorporation of accurate models of the main image degrading factors. Improvements of the data acquisition hardware can further increase image quality. In this paper, the image formation process of SPECT, including image-degrading factors, is explained. In addition, reconstruction algorithms and hardware modifications are reviewed, and their effects on image quality are illustrated with physical phantom and simulation experiments.


📜 SIMILAR VOLUMES


Image filtering in single-photon emissio
✍ K. Van Laere; M. Koole; I. Lemahieu; R. Dierckx 📂 Article 📅 2001 🏛 Elsevier Science 🌐 English ⚖ 120 KB

Among the factors contributing to optimal image quality in single-photon emission computed tomography (SPECT), image filtering is an important, though mostly subjectively applied, image-processing parameter. We have aimed at giving an overview of current available SPECT filtering options. Current SP

Automated image registration of gated ca
✍ Usaf E. Aladl; Gilbert A. Hurwitz; Damini Dey; David Levin; Maria Drangova; Piot 📂 Article 📅 2004 🏛 John Wiley and Sons 🌐 English ⚖ 568 KB

## Abstract ## Purpose To develop an automatic registration method for electrocardiogram‐gated myocardial perfusion single‐photon emission computed tomography (SPECT) and cardiac cine‐magnetic resonance imaging (MRI). ## Materials and Methods Paired myocardial perfusion SPECT (MPS) and MRI from