𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Improved three-dimensional GRASE imaging with the SORT phase-encoding strategy

✍ Scribed by John P. Mugler III


Book ID
101312696
Publisher
John Wiley and Sons
Year
1999
Tongue
English
Weight
248 KB
Volume
9
Category
Article
ISSN
1053-1807

No coin nor oath required. For personal study only.

✦ Synopsis


The phase-encoding strategy plays a critical role in determining the quality of gradient-and spin-echo (GRASE) images. Phase-encoding methods developed for two-dimensional GRASE imaging strive to achieve a balance between artifacts from T2-dependent signal amplitude modulations and off-resonance-dependent signal phase shifts, although no current method provides smooth and nonperiodic evolutions for both of these signal changes. In three-dimensional GRASE imaging, the use of two phase-encoding directions presents the opportunity for improved phaseencoding strategies. In this report a phase-encoding strategy for three-dimensional GRASE, termed SORT, is described; this strategy separates off-resonance and T2 effects, mapping one along each of the two phase-encoding directions. Thus, off-resonance-induced artifacts can be minimized while eliminating T2-dependent periodic signal modulations and allowing complete flexibility in the selection of echo time. The performance of the SORT phaseencoding method for T2-weighted GRASE imaging was compared with that of existing methods based on calculated point spread functions and simulated images. The predicted performance of SORT phase encoding was verified experimentally using T2-weighted three-dimensional GRASE imaging of the brain. Generally artifact-free images were obtained even in the presence of fat, susceptibility interfaces, and a wide range of T2 values. J. Magn. Reson.


📜 SIMILAR VOLUMES


Evaluation of free-breathing three-dimen
✍ Nicholas H. Bunce; Permi Jhooti; Jennifer Keegan; Shelley L. Rahman; Catherine B 📂 Article 📅 2001 🏛 John Wiley and Sons 🌐 English ⚖ 354 KB 👁 1 views

## Abstract We evaluated free‐breathing, prospective navigator‐gated, three‐dimensional (3D) magnetic resonance coronary angiography (MRCA) with hybrid ordered phase‐encoding (HOPE), in the detection of proximal coronary artery stenosis. The coronary arteries were imaged in 46 patients undergoing c

Three-dimensional navigator coronary MRA
✍ Martijn S. Dirksen; Theodorus A.M. Kaandorp; Hildo J. Lamb; J. Doornbos; Claire 📂 Article 📅 2003 🏛 John Wiley and Sons 🌐 English ⚖ 323 KB

## Abstract ## Purpose To evaluate the effect of including the first‐pass of a blood pool agent (BPA) on the image quality of three‐dimensional navigator coronary MRA. ## Materials and Methods A pig model was used to perform: 1) T1 simulation of the BPA, based on actual blood samples, and 2) BPA