𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Improved Detection of Human Antibodies to a Plasmodium Antigen Using a Peptide Modified with Aib Residues

✍ Scribed by Marc Bossus; Lbachir Mohammed; Arthuro Londono; Bernard Barbier; André Tartar; Pierre Druilhe; Héléne Gras-Masse


Publisher
John Wiley and Sons
Year
1997
Tongue
English
Weight
114 KB
Volume
3
Category
Article
ISSN
1075-2617

No coin nor oath required. For personal study only.

✦ Synopsis


A 17-mer sequence was selected as a model to study the influence of modifications of terminal ends both on the conformational of a peptide and on its antigenicity towards naturally developing antibodies. This sequence corresponded to a tandemly repeated motif, found in a long repetitive region, with high helical propensity, of a Plasmodium falciparum liver-stage antigen (LSA-1), immunogenic in man. Our model peptide was synthesized with ionizable or non-ionizable ends, or modified in both extremities by introduction of the helix-promoting residue alpha-aminoisobutyric acid (Aib). Helical contribution, absent in the 17 amino-acid sequence possessing ionizable ends, was detectable when non-ionizable ends were introduced, and dramatically increased in the Aib-modified analogue. The presence of ionizable ends totally abolished reactivity towards human sera, otherwise detectable with the peptide possessing non-ionizable ends. While modification by Aib residues was neither detrimental nor beneficial to antigenicity in solution, it clearly resulted in an improved sensitivity of the specific antibody detection when used as solid-phase antigen in ELISA.


📜 SIMILAR VOLUMES


Evaluation of a dual-wavelength size exc
✍ Michael D. Bond; Mark E. Panek; Zheru Zhang; Dana Wang; Promod Mehndiratta; Hui 📂 Article 📅 2010 🏛 John Wiley and Sons 🌐 English ⚖ 380 KB

The evaluation of a dual wavelength size exclusion high performance liquid chromatography (DW-SE-HPLC) method with improved sensitivity to detect aggregates in a high concentration IgG1 monoclonal antibody formulation is presented. This technique utilizes ultraviolet detection at two different wavel

Erratum: Hashida S, Hashinaka K, Ishikaw
📂 Article 📅 1998 🏛 John Wiley and Sons 🌐 English ⚖ 7 KB 👁 2 views

More reliable diagnosis of infection with human immunodeficiency virus type 1 (HIV-1) by detection of antibody IgGs to pol and gag proteins of HIV-1 and p24 antigen of HIV-1 in urine, saliva and/or serum with highly sensitive and specific enzyme immunoassay (immune complex transfer enzyme immunoassa