𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Improved deconvolution of perfusion MRI data in the presence of bolus delay and dispersion

✍ Scribed by Lisa Willats; Alan Connelly; Fernando Calamante


Publisher
John Wiley and Sons
Year
2006
Tongue
English
Weight
499 KB
Volume
56
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Cerebral blood flow (CBF) is commonly estimated from the maximum of the residue function deconvolved from bolus‐tracking data. The bolus may become delayed and/or dispersed in the vessels feeding the tissue, resulting in the calculation of an effective residue function, R~eff~(t), whose shape reflects the distortion of the bolus as well as the hemodynamic tissue status. Consequently the CBF is often underestimated. Since regularizing the deconvolution introduces additional distortions to R~eff~(t), it is impossible to distinguish a true decrease in the CBF from bias introduced by abnormal vasculature. This may result in misidentification of tissue regions at risk of infarction, which could have serious clinical consequences. We propose a modified maximum‐likelihood expectation‐maximization (mML‐EM) method, which is shown by way of simulations to improve the characterization of R~eff~(t) across a wide range of shapes. A pointwise termination approach for the iteration minimizes the effects of noise, and appropriate integral approximations minimize discretization errors. mML‐EM was applied to data from a patient with left internal carotid artery (ICA) occlusion. The shape of each calculated R~eff~(t) was used to create a map indicating voxels affected by bolus delay and/or dispersion, where CBF estimates are inherently unreliable. Such maps would be a useful adjunct for interpreting bolus‐tracking data. Magn Reson Med, 2006. © 2006 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Reexamining the quantification of perfus
✍ Linda Ko; Marina Salluzzi; Richard Frayne; Michael Smith 📂 Article 📅 2007 🏛 John Wiley and Sons 🌐 English ⚖ 117 KB

## Abstract ## Purpose To determine the true impact of dispersion upon cerebral blood flow (CBF) quantification by removing an algorithm implementation‐induced systematic error. ## Materials and Methods The impact of dispersion on the arterial input function (AIF) between measurement and entry i

Bolus dispersion issues related to the q
✍ Fernando Calamante 📂 Article 📅 2005 🏛 John Wiley and Sons 🌐 English ⚖ 344 KB

## Abstract Quantification of cerebral blood flow (CBF) using dynamic‐susceptibility contrast (DSC) MRI relies on the deconvolution of the arterial input function (AIF). The AIF is commonly measured in a major artery (e.g., the middle cerebral artery), and the estimated function is used as a global

Improving the prediction of final infarc
✍ Stephen E. Rose; Andrew L. Janke; Mark Griffin; Mark W. Strudwick; Simon Finniga 📂 Article 📅 2004 🏛 John Wiley and Sons 🌐 English ⚖ 302 KB

## Abstract ## Purpose To investigate whether bolus delay‐corrected dynamic susceptibility contrast (DSC) perfusion MRI measures allowed a more accurate estimation of eventual infarct volume in 14 acute stroke patients using a predictive tissue classifier algorithm. ## Materials and Methods Tiss