Improved calibration technique for in vivo proton MRS thermometry for brain temperature measurement

✍ Scribed by M. Zhu; A. Bashir; J.J. Ackerman; D.A. Yablonskiy


Publisher
John Wiley and Sons
Year
2008
Tongue
English
Weight
380 KB
Volume
60
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

The most common MR‐based approach to noninvasively measure brain temperature relies on the linear relationship between the ^1^H MR resonance frequency of tissue water and the tissue's temperature. Herein we provide the most accurate in vivo assessment existing thus far of such a relationship. It was derived by acquiring in vivo MR spectra from a rat brain using a high field (11.74 Tesla [T]) MRI scanner and a single‐voxel MR spectroscopy technique based on a LASER pulse sequence. Data were analyzed using three different methods to estimate the ^1^H resonance frequencies of water and the metabolites NAA, Cho, and Cr, which are used as temperature‐independent internal (frequency) references. Standard modeling of frequency‐domain data as composed of resonances characterized by Lorentzian line shapes gave the tightest resonance‐frequency versus temperature correlation. An analysis of the uncertainty in temperature estimation has shown that the major limiting factor is an error in estimating the metabolite frequency. For example, for a metabolite resonance linewidth of 8 Hz, signal sampling rate of 2 Hz and SNR of 5, an accuracy of approximately 0.5°C can be achieved at a magnetic field of 3T. For comparison, in the current study conducted at 11.74T, the temperature estimation error was approximately 0.1°C. Magn Reson Med 60:536–541, 2008. © 2008 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Comparison of methods for reduction of l
✍ Andreas Ebel; Andrew A. Maudsley 📂 Article 📅 2001 🏛 John Wiley and Sons 🌐 English ⚖ 199 KB 👁 1 views

## Abstract In vivo proton MR spectroscopic imaging (MRSI) of human brain is complicated by the presence of a strong signal from subcutaneous lipids, which may result in signal contamination in metabolite images obtained following Fourier‐transform reconstruction. In this study, two approaches for

An improved thermocouple technique for m
✍ Masashi Katsuki; Yukio Mizutani; Yasushi Matsumoto 📂 Article 📅 1987 🏛 Elsevier Science 🌐 English ⚖ 687 KB

When we use an electrically compensated thermocouple for its frequency response to measure temperatures in turbulent flames, considerable errors occur due to the temperature-and velocity-dependences of time constant of response, as well as surface reactions and radiative heat losses. An improved met

Single-shot two-echo technique for simul
✍ In-Young Choi; Sang-Pil Lee; Hellmut Merkle; Jun Shen 📂 Article 📅 2004 🏛 John Wiley and Sons 🌐 English ⚖ 189 KB 👁 1 views

## Abstract A single‐shot, two‐echo method for the simultaneous detection of multiple‐quantum (MQ)‐filtered γ‐aminobutyric acid (GABA) and creatine (Cr) was developed and demonstrated in the human brain in vivo at 3 Tesla. The simultaneously measured Cr singlet served as a navigator for the spectra

On the use of two-dimensional-J NMR meas
✍ Dr. Wolfgang Dreher; Dieter Leibfritz 📂 Article 📅 1995 🏛 John Wiley and Sons 🌐 English ⚖ 681 KB

## Abstract The potential of two‐dimensional (2D)‐J NMR for __in vivo__ proton MRS is examined. Single voxel measurements on the rat brain were performed at 4.7 T using point‐resolved spectrocopy localization with a voxel size of 64 μl and total measuring times of 10‐15 min. It is shown that a seri