𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Implications of pulse sequence in structural imaging of trabecular bone

✍ Scribed by Aranee Techawiboonwong; Hee Kwon Song; Jeremy F. Magland; Punam K. Saha; Felix W. Wehrli


Book ID
102373392
Publisher
John Wiley and Sons
Year
2005
Tongue
English
Weight
316 KB
Volume
22
Category
Article
ISSN
1053-1807

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Purpose

To investigate the SNR and image properties of 3D steady‐state free precession (SSFP), fast large‐angle spin echo (FLASE), gradient‐recalled acquisition in steady state (GRASS), and spoiled GRASS (SPGR) for structural imaging of trabecular bone (TB).

Materials and Methods

SNR was examined theoretically and experimentally on phantoms, bone specimens, and in vivo. The bone volume fraction, TB thickness, and echo time (TE) dependence of the thickness were compared. The trabecula was modeled as a cylinder in simulations to examine the intravoxel spin‐dephasing in SSFP and GRASS. Images were acquired on a 1.5T Siemens Sonata system (40 mT/m maximum gradient, 200 T/m/s peak slew rate).

Results

Within the hardware and safety limit constraints, SNR of FLASE was superior, followed by SSFP, GRASS, and SPGR. The trabecular thickness derived from gradient‐echo images was 10–45% greater than that obtained with FLASE. Conversely, SSFP images delineated partial volume trabeculae better than FLASE. Simulations indicated that the artifactual thickening was more severe in SSFP than in GRASS, which was attributed to off‐resonance effects from the induced gradients at the bone/marrow interface.

Conclusion

FLASE had the highest SNR and was insensitive to susceptibility dephasing. Although SSFP has superior SNR compared to GRASS, off‐resonance effects and duty cycle limitations may compromise its practicality in this application. J. Magn. Reson. Imaging 2005. © 2005 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Fast Low-Angle Dual Spin-Echo (FLADE): A
✍ J. Magland; B. Vasilic; F. W. Wehrli 📂 Article 📅 2006 🏛 John Wiley and Sons 🌐 English ⚖ 704 KB

## Abstract Mechanical strength and fracture resistance of trabecular bone (TB) are largely determined by the structural arrangement of individual trabeculae. Fast 3D spin‐echo approaches are preferable to gradient echoes in that they are less sensitive to local induced gradients at the bone/marrow

Quantitative high-resolution magnetic re
✍ Felix W. Wehrli; Mary B. Leonard; Punam K. Saha; Bryon R. Gomberg 📂 Article 📅 2004 🏛 John Wiley and Sons 🌐 English ⚖ 706 KB

## Abstract ## Purpose To explore the potential role of micro‐magnetic resonance imaging (μ‐MRI) for quantifying trabecular and cortical bone structural parameters in renal osteodystrophy (ROD), a multifactorial disorder of bone metabolism, traditionally evaluated by bone biopsy. ## Materials and