Impact of lung volume on MR signal intensity changes of the lung parenchyma
✍ Scribed by Alexander A. Bankier; Carl R. O'Donnell; Vu M. Mai; Pippa Storey; Viviane De Maertelaer; Robert R. Edelman; Qun Chen
- Book ID
- 102374996
- Publisher
- John Wiley and Sons
- Year
- 2004
- Tongue
- English
- Weight
- 267 KB
- Volume
- 20
- Category
- Article
- ISSN
- 1053-1807
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Purpose
To test the hypothesis that, in magnetic resonance (MR) imaging of healthy individuals, equal relative changes in lung volume cause equal relative changes in MR signal intensity of the lung parenchyma.
Materials and Methods
In two experimental runs, 10 volunteers underwent spirometrically monitored MR imaging of the lungs, with MR images acquired at 10 incremental lung volumes ranging from total lung capacity to 10% above residual volume. Average signal intensity, signal variability, and signal intensity integrals were calculated for each volunteer and for each lung volume. The effect of lung volume on signal intensity was quantified using linear regression analysis complemented by the runs test. Slopes and intercepts of regression lines were compared with an analysis of covariance. Slopes of the lines of best fit for lung volumes and signal intensities from the two runs were compared to the slope of the line of identity. Comparisons between the two runs were visualized using Bland and Altman plots.
Results
The slopes of the 10 individual regression lines yielded no significant differences (F = 1.703, P = 0.101; F = 1.321, P = 0.239). The common slopes were –0.556 ± 0.027 (P = 0.0001) for the first and –0.597 ± 0.0031 (P = 0.0001) for the second experimental run. Both slopes displayed no significant nonlinearity (P = 0.419 and P = 0.067). There was a strong association between changes in lung volumes (r~s~ = 0.991, P = 0.0001) and changes in signal intensity (r~s~ = 0.889, P = 0.0001) in the two experimental runs. Lines of best fit for lung volume and signal intensities were not significantly different from the slope of the line of identity (P = 0.321 and P = 0.212, respectively).
Conclusion
Equal changes in lung volume cause equal changes in MR signal intensity of the lung parenchyma. This linear and reproducible phenomenon could be helpful in comparing pulmonary MR signal intensity between individuals. J. Magn. Reson. Imaging 2004;20:961–966. © 2004 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
## Abstract ## Purpose To investigate the validity of the fetal right lung‐to‐liver signal intensity ratio (LLSIR) for prediction of postnatal outcomes in left‐sided congenital diaphragmatic hernia (CDH) ## Materials and Methods The study included 14 pregnant women who underwent MR exams for eva
## Abstract The effect of lung inflation on arterial spin‐labeling signal in lung perfusion is investigated. Arterial spin‐labeling schemes, called alternation of selective inversion pulse (ASI) and its hybrid (HASI), which uses blood water as an endogenous, freely diffusible tracer, were applied t
The purpose of this study was to determine the effect of respiratory phase on signal intensity of the lung. Lung images were obtained from eleven healthy human volunteers using a multiple inversion recovery segmented turbo spin echo sequence (MIR-TSE). MIR exploits the difference in T(1) between dif
## Abstract Radial acquisition (RA) techniques have been extended to produce isotropic, three‐dimensional images of lung in live laboratory animals at spatial resolution down to 0.013 mm^3^ with a signal‐to‐noise ratio of 30:1. The pulse sequence and reconstruction algorithm have been adapted to al