The main goal of this work is to determine the capabilities of the Medipix2 and Timepix devices for imaging in X-ray fluorescence (XRF) analysis. The energy resolution of these devices is not sufficient for identification of characteristic radiation in each pixel. The proposed method of per pixel sp
The ALICE Silicon Pixel Detector (SPD) forms the two innermost layers of the ALICE Inner Tracking System (ITS). It consists of two barrel layers of hybrid silicon pixel detectors at radii of 39 and 76 mm. The physics targets of the ALICE experiment require that the material budget of the SPD is kept