Resin-modified glass ionomer cements are a recent development in which the desirable properties of glass ionomer cements and resin-composites are combined. The presence of resin may, however, retard the acid-base reaction of the ionomer component. This has led to a debate regarding the classificatio
Hydrolytic degradation and cracks in resin-modified glass-ionomer cements
β Scribed by Fano, Luca ;Fano, Vincenzo ;Ma, Wanyun ;Wang, Xiaoguang ;Zhu, Feng
- Publisher
- John Wiley and Sons
- Year
- 2004
- Tongue
- English
- Weight
- 389 KB
- Volume
- 69B
- Category
- Article
- ISSN
- 0021-9304
No coin nor oath required. For personal study only.
β¦ Synopsis
Water-absorption affects the basic properties of resin-modified glass-ionomer cements (RMGICs). Fick's law is usually invoked to explain the absorption process. The purpose of this study is to show that the absorption in accordance with the Fickian model cannot be extended to the whole of the specimen, and that microcrack formation is the main degradation mechanism for specimens cured in a closed environment. For this purpose, flat disk-shaped paste specimens 1.5 mm thick (aspect ratio 4), irradiated in closed conditions between two glass slides and stored in water for approximately 20 months, were analyzed periodically gravimetrically and under confocal fluorescence microscopy, with absorbed eosin used as the fluorescent probe. At pH 7.0, the specimen surface (10-20 micrometers in depth) absorbed water rapidly, swelled, and disintegrated in 20-40 days. Long-term storage produced isolated cracks and grains, no progress in the swelling, and a slow weight decrease. A lower pH (pH 3.5) produced a significant increase of the number of microcracks. The decrease in the irradiation time (30 s or less) enhanced the erosion process, producing very broad cracks. It was concluded that the prevalent mechanism of long-term hydrolytic degradation was based on the slow formation of cracks, whereas only in the early stage of storage did absorption occur quickly in accordance with the Fickian diffusion.
π SIMILAR VOLUMES
Resin-modified glass ionomer cements (RM-GICs) are the last generation of GICs commonly used in restorative dentistry. They contain various resins that improve their mechanical properties. These modifications, however, may also affect their biocompatibility. We compared the cytotoxicity of seven bio
## Abstract This study quantified the release of monomers from polymerized specimens of four commercially available resin composites and one glass ionomer cement immersed in water:ethanol solutions. Individual standard curves were prepared from five monomers: (1) triethylene glycol dimethacrylate (
## Abstract It was the aim of the present experiments to evaluate the fluoride leaching of four compomers and one resinβmodified glassβionomer cement (gic) into aqueous media over a 1βyear period. Various extraction/equilibrium solutions were applied to simulate important intraoral parameters. Spec