𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Hydrogels based on poly(ethylene oxide) and poly(tetramethylene oxide) or poly(dimethyl siloxane). III.In vivo biocompatibility and biostability

✍ Scribed by Hyung Park, Jae ;Bae, You Han


Publisher
John Wiley and Sons
Year
2003
Tongue
English
Weight
190 KB
Volume
64A
Category
Article
ISSN
0021-9304

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

To investigate the effects of polymer chemistry and topology (linear or graft copolymer) on in vivo biocompatibility and biostability based on cage implant system, various hydrogels, composed of short hydrophilic [polyethylene oxide (PEO)] and hydrophobic block, were prepared by polycondensation reaction. Poly(tetramethylene oxide) (PTMO) or poly(dimethyl siloxane) (PDMS) was chosen as a hydrophobic block because of their wide utilization as a biomaterial. By using the specimens retrieved from rats killed after 1, 2, 3, 5, and 7 weeks' implantation, cellular and material responses were assessed. Most hydrogels showed a comparable value of macrophage density to Pellethane®, control polymer, whereas they did significantly lower foreign body giant cell (FBGC) density and coverage because of the presence of PEO. However, PEO block length and polymer topology did not affect macrophage adhesion and FBGC formation in our polymer composition. The hydrogel based on PDMS alone showed significantly lower macrophage density and FBGC density than Pellethane®, indicating that PDMS plays a role in inhibiting cellular adhesion. The results obtained from gel permeation chromatography curve and Fourier transform infrared spectra exhibited that all the polymers were susceptible to oxidative degradation in vivo. Although Pellethane® revealed surface degradation by 5 weeks in vivo, hydrogels showed rapid degradation in the bulk within 2 weeks because of the penetration of oxidative chemicals released from phagocytic cells into PEO domain of phase‐separated hydrogels. The more significant degradation was observed in the hydrogels with longer PEO block and PTMO as a hydrophobic block instead of PDMS. It was evident that the minor degradation could be achieved by grafting PEO and adopting PDMS as a hydrophobic block in the hydrogel. © 2002 Wiley Periodicals, Inc. J Biomed Mater Res 64A: 309–319, 2003


📜 SIMILAR VOLUMES


Injectable drug-delivery systems based o
✍ Li, Jun ;Ni, Xiping ;Leong, Kam W. 📂 Article 📅 2003 🏛 John Wiley and Sons 🌐 English ⚖ 123 KB

## Abstract Polymeric hydrogels long have attracted interest for biomaterials applications because of their generally favorable biocompatibility. High in water content, they are particularly attractive for delivery of delicate bioactive agents, such as proteins. However, because they require covale

Supramolecular hydrogels based on inclus
✍ Xu Li; Jun Li 📂 Article 📅 2008 🏛 John Wiley and Sons 🌐 English ⚖ 159 KB

## Abstract Supramolecular hydrogels formed through inclusion complexation between high molecular weight poly(ethylene oxide) (PEO) and α‐cyclodextrin (α‐CD) showed the most sustained release kinetics __in vitro__ with molecular weight of PEO of 35,000 within 5 days. To improve the sustained releas