𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Hydrodynamics and heat transfer in swirl flow under conditions of one-side heating. Part 2: Boiling heat transfer. Critical heat fluxes

✍ Scribed by Aleksey V. Dedov; Alexander T. Komov; Alexander N. Varava; Victor V. Yagov


Publisher
Elsevier Science
Year
2010
Tongue
English
Weight
582 KB
Volume
53
Category
Article
ISSN
0017-9310

No coin nor oath required. For personal study only.

✦ Synopsis


The paper gives the basic results of experimental investigation of boiling heat transfer in heat-absorbing devices of the ITER thermonuclear reactor, which are subjected to one-side heating. The experimental data on heat transfer at nucleate and film boiling and on critical heat fluxes are obtained in the following range of parameters of water flow: pressure p = 0.7-2.0 MPa, mass flux G = 340-25 000 kg/(m 2 s), and water temperature at the inlet T in = 20-60 Β°C. A twisted tape is inserted in the circular channel in order to form swirling flow of water. The investigations are performed for tapes with different values of flow swirl coefficient, as well for test sections without a tape. Appropriate calculation formulas are derived, which reliably generalize the experimental data.


πŸ“œ SIMILAR VOLUMES


Hydrodynamics and heat transfer in swirl
✍ Aleksey V. Dedov; Alexander T. Komov; Alexander N. Varava; Victor V. Yagov πŸ“‚ Article πŸ“… 2010 πŸ› Elsevier Science 🌐 English βš– 557 KB

The paper gives the basic results of experimental investigation of hydrodynamics and heat transfer in heat-absorbing devices of the ITER thermonuclear reactor, which are subjected to one-side heating. The entire array of experimental data is obtained in the following range of parameters of water flo

Heat transfer for flow boiling of water
✍ Toshiyuki Kobayashi; Kaichiro Mishima πŸ“‚ Article πŸ“… 2002 πŸ› John Wiley and Sons 🌐 English βš– 411 KB πŸ‘ 1 views

## Abstract Heat transfer for flow boiling of water and critical heat flux (CHF) experiments in a half‐circumferentially heated round tube under low‐pressure conditions were carried out. To clarify the flow patterns in the heated section, experiments in the round tube under the same conditions were

Erratum to β€œFlow boiling of liquid nitro
✍ S.L. Qi; P. Zhang; R.Z. Wang; L.X. Xu πŸ“‚ Article πŸ“… 2009 πŸ› Elsevier Science 🌐 English βš– 107 KB

In Eqs. ( 14) and ( 16) of the above article, one item depicting the inlet subcooling of the liquid nitrogen was inadvertently missing when the manuscript was prepared. This item is formulated as