𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Hydraulic characteristics of aerobic granules using size exclusion chromatography

✍ Scribed by Sunil S. Adav; Cheng-Hsuan Chang; Duu-Jong Lee


Publisher
John Wiley and Sons
Year
2008
Tongue
English
Weight
393 KB
Volume
99
Category
Article
ISSN
0006-3592

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Elution of poly(ethylene glycol) of molecular weight 200–20,000 Da from a size exclusion chromatography column packed with phenol‐fed aerobic granules of three different nominal sizes (types I–III) has been investigated. The pore sizes of the three types of granules were evaluated based on the mean hydraulic times of the elution curves that decreased directly proportional to the increased logarithm of the molecular mass of a standard tracer and increased as granule size decreased. The corresponding exclusion limits for types I–III granules were 139,000, 123,000, and 54,500 Da, respectively. A one‐dimensional convection–dispersion model described the effective dispersion coefficients of the tracers through the granule column. The intra‐granular permeabilities and convective and diffusional transit times through the granule interior were evaluated by a dual porosity model. For small molecules of molecular mass <5,000 Da, intra‐granular convection dominated transport mechanisms at fast moving velocity. For comparatively larger molecules, diffusion barrier existed to limit nutrient supply to the granules. The size exclusion test provided intra granular transport characteristics using detailed analysis on the elution data. Biotechnol. Bioeng. 2008;99: 791–799. © 2007 Wiley Periodicals, Inc.


📜 SIMILAR VOLUMES


Viral clearance using surfactant-aided s
✍ D. A. Horneman; M. Ottens; L. A. M. van der Wielen; J. T. F. Keurentjes 📂 Article 📅 2007 🏛 American Institute of Chemical Engineers 🌐 English ⚖ 308 KB

## Abstract Surfactant‐aided size‐exclusion chromatography (SASEC) is applied to the viral clearance of blood proteins, taking BSA as an example. Fixed bed systems as well as simulated moving bed (SMB) systems are examined. SASEC shows a better performance of this separation in terms of log reducti

Technical note: Removal of metal ion inh
✍ Carney D. Matheson; Travis E. Marion; Shana Hayter; Neal Esau; Renee Fratpietro; 📂 Article 📅 2009 🏛 John Wiley and Sons 🌐 English ⚖ 229 KB

## Abstract A novel technique for the removal of metal ions inhibiting DNA extraction and PCR of archaeological bone extracts is presented using size exclusion chromatography. Two case studies, involving copper inhibition, demonstrate the effective removal of metal ion inhibition. Light microscopy,

Assessment of errors in the determinatio
✍ Michelle L. Coote; Thomas P. Davis 📂 Article 📅 1999 🏛 John Wiley and Sons 🌐 English ⚖ 198 KB 👁 1 views

In this work, we present values for the Mark-Houwink-Sakurada (MHS) and Stockmayer-Fixman (SF) constants for a series of homopolymers of para-substituted styrenes (4-X-styrene; X ϭ OCH 3 , OCH 2 CH 3 , CH 3 , F, Cl, and Br) in THF at room temperature. The respective values of K (in 10 Ϫ5 dL/g) and ␣