๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

Highly Selective Perchlorate Membrane Electrode Based on Cobalt(III) Schiff Base as a Neutral Carrier

โœ Scribed by Ardeshir SHOKROLLAHI; Mehrorang GHAEDI; Hamid Reza RAJABI; Ali Hossein KIANFAR


Publisher
John Wiley and Sons
Year
2009
Tongue
English
Weight
109 KB
Volume
27
Category
Article
ISSN
0256-7660

No coin nor oath required. For personal study only.

โœฆ Synopsis


A highly selective poly(vinyl chloride) (PVC) membrane electrode based on Co(III)-Schiff base [Co(5-NO 2 -Salen)(PBu 3 )]ClO 4 โ€ขH 2 O (where 5-NO 2 -SalenH๏ผbis(5-nitrosalycilaldehyde)ethylenediamine) as a new carrier for construction of perchlorate-selective electrode by incorporating the membrane ingredients on the surface of a graphite electrodes has been reported. The proposed electrode possesses a very wide Nernestian potential linear range to perchlorate from 1.0ร—10 -6 to 5.0ร—10

-1 molโ€ขL -1 with a slope of (59.4ยฑ0.9) mV per decade of perchlorate concentration with a low detection limit of 5.0ร—10 -7 molโ€ขL -1 and good perchlorate selectivity over the wide variety of other anions. The developed electrode has an especially fast response (๏ผœ5 s) and a wide pH independent range (3.0-12.0) in comparison with recent reported electrodes and can be used for at least 2 months without any considerable divergence in their potential response. This electrode was used for the determination of perchlorate in river water, drinking water, sludgy water and human urine with satisfactory results without complicated and time consuming pretreatment.


๐Ÿ“œ SIMILAR VOLUMES


Al(III)โ€“Selective Electrode Based on Fur
โœ M. F. Mousavi; M. Arvand-Barmchi; M. A. Zanjanchi ๐Ÿ“‚ Article ๐Ÿ“… 2001 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 68 KB ๐Ÿ‘ 1 views

A PVC membrane electrode for aluminum(III) ions based on Furil (ethan dione, di-(2-furyl)) as neutral carrier was prepared. The electrode exhibits a near Nernstian response for Al 3รพ ions over a wide concentration range (1.0610 76 to 1.0610 72 mol dm 73 ) with a limit of detection 1.3610 77 mol dm 7

Highly Selective Chromium(III) PVC-Membr
โœ Mojtaba Shamsipur; Ahmad Soleymanpour; Morteza Akhond; Hashem Sharghi; Moonaโ€…Hos ๐Ÿ“‚ Article ๐Ÿ“… 2005 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 180 KB ๐Ÿ‘ 1 views

Three recently synthesized Schiffs bases were studied to characterize their ability as Cr 3รพ ion carrier in PVCmembrane electrodes. The polymeric membrane (PME) and coated glassy carbon (CGCE) electrodes based on 2hydroxybenzaldehyde-O,O'-(1,2-dioxetane-1,2-diyl) oxime (L1) exhibited Nernstian respo

Highly Selective and Sensitive Tin(II) M
โœ Morteza Hosseini; Hayedeh Bagheriโ€…Sadeghi; Mohammad Rahimi; Masoud Salavati-Nias ๐Ÿ“‚ Article ๐Ÿ“… 2009 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 270 KB ๐Ÿ‘ 1 views

## Abstract Studies on complex formation of tris(3โ€(2โ€hydroxybenzophenone)propyl)amine (THPA) with a number of metal ions in acetonitrile solution revealed the occurrence of a selective 1โ€‰:โ€‰1 complexation of the proposed ligand with Sn^2+^ ion. Consequently, THPA was used as a suitable neutral iono