𝔖 Bobbio Scriptorium
✦   LIBER   ✦

High-throughput liquid-chromatography method with fluorescence detection for reciprocal determination of furosemide or norfloxacin in human plasma

✍ Scribed by Toma Galaon; Stefan Udrescu; Iulia Sora; Victor David; Andrei Medvedovici


Publisher
John Wiley and Sons
Year
2006
Tongue
English
Weight
529 KB
Volume
21
Category
Article
ISSN
0269-3879

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

A simple, high‐throughput, highly selective and sensitive HPLC‐FLD method for isolation and determination of furosemide and/or norfloxacin in human plasma samples following a simple organic solvent deproteinization step with acetonitrile as sample ‘clean‐up’ procedure is reported. One of the two drug substances plays the internal standard role for the determination of the other. Separation of analyte and internal standard was achieved in less than 5.3 min (injection to injection) on a Chromolith Performance RP‐18e column, using an aqueous component containing 0.015 mol/L sodium heptane‐sulfonate and 0.2% triethylamine brought to pH = 2.5 with H~3~PO~4~. The composition of the mobile phase was: acetonitrile–methanol–aqueous component = 70:15:15 (v/v/v) and the flow‐rate was set up to 3 mL/min. The chromatographic method applied to the determination of furosemide relies on fluorescent detection parameters of 235 nm for the excitation wavelength, and 402 nm for the emission wavelength. In case of norfloxacin, the excitation wavelength is set up to 268 nm and the emission wavelength is set up to 445 nm. The overall method leads to quantitation limits of about 27 ng/mL for furosemide, and 19.5 ng/mL for norfloxacin, using an injection volume of 250 µL. The method was applied to the bioequivalence study of two furosemide‐containing formulations. Copyright © 2006 John Wiley & Sons, Ltd.


📜 SIMILAR VOLUMES


Determination of atrasentan by high perf
✍ Peter D. Bryan; Lisa B. Sapochak; Michelle M. Tames; Robert J. Padley; Tawakol A 📂 Article 📅 2001 🏛 John Wiley and Sons 🌐 English ⚖ 108 KB 👁 2 views

Atrasentan is an endothelin antagonist selective for the ET A receptor in development at Abbott Laboratories for the treatment of cardiovascular disease and cell proliferation disorders. A simple and sensitive chromatographic method for the determination of atrasentan in human plasma has been develo

High-performance liquid chromatographic
✍ A. Lagana; A. Marino; M. Rotatori; R. Curini; G. D'Ascenzo; L. Miano 📂 Article 📅 1988 🏛 Elsevier Science 🌐 English ⚖ 290 KB

A high-performance liquid chromatographic analysis with fluorimetric detection is described for the quantitative determination of norfloxacin in renal, prostatic tissues and in plasma. The analytical procedure in the tissue pretreatment, consists of purification of the obtained sample by a solid sta