A high speed gas pumping system is required to minimize the reionization loss of neutral beams in a neutral beam injector; until now the beam line design has made use of a condensation cryopump system. The system becomes more expensive as size increases and needs high maintenance and has a high oper
High specific pumping cryopanel for LHD neutral beam injector
โ Scribed by O. Kaneko; A. Ando; T. Kuroda; Y. Oka; Y. Takeiri; K. Tsumori; K. Yamamoto; K. Wakabayashi; Y. Iwasa; T. Kai
- Publisher
- Elsevier Science
- Year
- 1993
- Tongue
- English
- Weight
- 308 KB
- Volume
- 20
- Category
- Article
- ISSN
- 0920-3796
No coin nor oath required. For personal study only.
โฆ Synopsis
A high specific pumping cryopump system is designed for the neutral beam injector of the Large Helical Device (LHD NBI). The cryopump consists of several module panels that have the radiation shield of louver blind baffle structure. Two types of the louver blind baffle are designed, and both show the particle transparent efficiency over 50% according to the Monte Carlo simulation. This prediction was confirmed by test on the small model cryopump. The engineering models of these pumps, with a pumping speed of 450 m3/s each, are now under construction for the test stand of LHD NBI.