𝔖 Bobbio Scriptorium
✦   LIBER   ✦

High sensitivity analysis of proteins and peptides by capillary electrophoresis-tandem mass spectrometry: Recent developments in technology and applications

✍ Scribed by Dr. Daniel Figeys; Ruedi Aebersold


Publisher
John Wiley and Sons
Year
1998
Tongue
English
Weight
1023 KB
Volume
19
Category
Article
ISSN
0173-0835

No coin nor oath required. For personal study only.

✦ Synopsis


Analytical biochemistry, in particular the analysis of regulatory proteins that control biological systems and pathways, is dependent on methods of ever-increasing sensitivity. Capillary electrophoresis (CE) has long been recognized as an ultrasensitive analytical technique. In spite of the high sensitivity, CE has not penetrated protein discovery research as a standard analytical method. In this review article we summarize recent technical developments which have significantly enhanced CE as a tool for the analysis of trace amounts of proteins. Specifically, we review recent advances in the development and application of capillary electrophoresis-mass spectrometry (CE-MS) and on-line analyte concentration techniques, and introduce the emerging field of microfluidics as a front end to mass spectrometry (MS).


πŸ“œ SIMILAR VOLUMES


Analysis of a Standard Peptide Mixture b
✍ H. J. Major; A. E. Ashcroft πŸ“‚ Article πŸ“… 1996 πŸ› John Wiley and Sons 🌐 English βš– 409 KB πŸ‘ 2 views

The combination of capillary electrophoresis with mass spectrometry allows efficient separation and identification of components in mixtures with greater specificity than can be obtained using capillary electrophoresis and ultra violet detection alone. For the mixture of peptides analysed in this ap

High-sensitivity analysis and sequencing
✍ Marina, Anabel; GarcΓ­a, Miguel Angel; Albar, Juan Pablo; YagΓΌe, JesΓΊs; LΓ³pez de πŸ“‚ Article πŸ“… 1999 πŸ› John Wiley and Sons 🌐 English βš– 203 KB πŸ‘ 2 views

This paper describes experience with the commercially available LCQ quadrupole ion trap mass spectrometer applied to the o †-line analysis of peptides and proteins. The standard front end of the electrospray probe was replaced with a micromanipulator which, with the aid of a magnifying device, allow

A robust approach for the analysis of pe
✍ Christian Neusüß; Matthias Pelzing; Marcus Macht πŸ“‚ Article πŸ“… 2002 πŸ› John Wiley and Sons 🌐 English βš– 228 KB πŸ‘ 1 views

A capillary electrophoresis-tandem mass spectrometry (CE-MS/MS) approach has been developed for routine application in proteomic studies. Robustness of the coupling is achieved by using a standard coaxial sheath-flow sprayer. Thereby, greater stability than nanoelectrospray ionization-mass spectrome