𝔖 Bobbio Scriptorium
✦   LIBER   ✦

High-resolution magnetic resonance angiography in the mouse using a nanoparticle blood-pool contrast agent

✍ Scribed by Gabriel P. Howles; Ketan B. Ghaghada; Yi Qi; Srinivasan Mukundan Jr.; G. Allan Johnson


Book ID
102532317
Publisher
John Wiley and Sons
Year
2009
Tongue
English
Weight
473 KB
Volume
62
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

High‐resolution magnetic resonance angiography is already a useful tool for studying mouse models of human disease. Magnetic resonance angiography in the mouse is typically performed using time‐of‐flight contrast. In this work, a new long‐circulating blood‐pool contrast agent—a liposomal nanoparticle with surface‐conjugated gadolinium (SC‐Gd liposomes)—was evaluated for use in mouse neurovascular magnetic resonance angiography. A total of 12 mice were imaged. Scan parameters were optimized for both time‐of‐flight and SC‐Gd contrast. Compared to time‐of‐flight contrast, SC‐Gd liposomes (0.08 mmol/kg) enabled improved small‐vessel contrast‐to‐noise ratio, larger field of view, shorter scan time, and imaging of venous structures. For a limited field of view, time‐of‐flight and SC‐Gd were not significantly different; however, SC‐Gd provided better contrast‐to‐noise ratio when the field of view encompassed the whole brain (P < 0.001) or the whole neurovascular axis (P < 0.001). SC‐Gd allowed acquisition of high‐resolution magnetic resonance angiography (52 × 52 × 100 micrometer^3^ or 0.27 nL), with 123% higher (P < 0.001) contrast‐to‐noise ratio in comparable scan time (∼45 min). Alternatively, SC‐Gd liposomes could be used to acquire high‐resolution magnetic resonance angiography (0.27 nL) with 32% higher contrast‐to‐noise ratio (P < 0.001) in 75% shorter scan time (12 min). Magn Reson Med, 2009. © 2009 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Maximizing contrast-to-noise ratio in ul
✍ Maisie S. Wang; David R. Haynor; Gregory J. Wilson; Tim Leiner; Jeffrey H. Maki 📂 Article 📅 2007 🏛 John Wiley and Sons 🌐 English ⚖ 554 KB

## Abstract ## Purpose To determine sequence parameters that maximize vascular contrast‐to‐noise (CNR) for ultra‐high resolution equilibrium phase (EP) peripheral imaging for the blood pool agent (BPA) Vasovist. ## Materials and Methods A model for maximizing CNR in EP MR angiography (MRA) is pr

First-pass contrast-enhanced magnetic re
✍ Wei Li; Sean Tutton; Anthony T. Vu; Linda Pierchala; Belinda S.Y. Li; Jerome M. 📂 Article 📅 2004 🏛 John Wiley and Sons 🌐 English ⚖ 486 KB 👁 1 views

## Abstract ## Purpose To evaluate the feasibility of first‐pass contrast‐enhanced magnetic resonance angiography (MRA) using ferumoxytol in humans. ## Materials and Methods First‐pass and equilibrium phase MRA were performed using ferumoxytol in one healthy volunteer and 11 patients with a fast

Combined use of the intravascular blood-
✍ Robbert M. Maes; Jonathan S. Lewin; Jeffrey L. Duerk; Frank K. Wacker 📂 Article 📅 2005 🏛 John Wiley and Sons 🌐 English ⚖ 487 KB 👁 1 views

## Abstract ## Purpose To evaluate the combined use of carbon dioxide (CO~2~) and a gadolinium‐based blood‐pool agent for magnetic resonance angiography (MRA). ## Materials and Methods After an initial intravenous injection of the blood‐pool agent Gadomer (Schering AG, Germany), repeated transca

IRON magnetic resonance: a robust techni
✍ Gitsios Gitsioudis; Matthias Stuber; Ingolf Arend; Moritz Thomas; Jing Yu; Thoma 📂 Article 📅 2011 🏛 BioMed Central 🌐 English ⚖ 683 KB

Gitsioudis et al.: IRON magnetic resonance: a robust technique for angiography providing high blood-to-tissue contrast within the clinically approved dosage of superparamagnetic nanoparticles.