𝔖 Bobbio Scriptorium
✦   LIBER   ✦

High-resolution blood flow velocity measurements in the human finger

✍ Scribed by M. Klarhöfer; B. Csapo; Cs. Balassy; J.C. Szeles; E. Moser


Publisher
John Wiley and Sons
Year
2001
Tongue
English
Weight
173 KB
Volume
45
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

MR phase contrast blood flow velocity measurements in the human index finger were performed with triggered, nontriggered, and cine acquisition schemes. A strong (G~max~ = 200 mT/m), small bore (inner diameter 12 cm) gradient system inserted in a whole body 3 Tesla MR scanner allowed high‐resolution imaging at short echo times, which decreases partial volume effects and flow artifacts. Arterial blood flow velocities ranging from 4.9–19 cm/sec were measured, while venous blood flow was significantly slower at 1.5–7.1 cm/sec. Taking into account the corresponding vessel diameters ranging from 800 μm to 1.8 mm, blood flow rates of 3.0–26 ml/min in arteries and 1.2–4.8 ml/min in veins are obtained. The results were compared to ultrasound measurements, resulting in comparable blood flow velocities in the same subjects. Magn Reson Med 45:716–719, 2001. © 2001 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Measurement of blood flow velocity in th
✍ P. J. Martin; D. H. Evans; A. R. Naylor 📂 Article 📅 1995 🏛 John Wiley and Sons 🌐 English ⚖ 732 KB

Unlike conventional transcranial Doppler (TCD), transcranial color-coded sonography (TCCS) enables imaging of the basal cerebral arteries using color-flow ultrasonography and correction for the angle of insonation when determining blood flow velocities. We present hemodynamic data from 20 normal sub

Noninvasive measurement of the cerebral
✍ Kun Lu; Joanna E. Perthen; Robert O. Duncan; Linda M. Zangwill; Thomas T. Liu 📂 Article 📅 2008 🏛 John Wiley and Sons 🌐 English ⚖ 292 KB

## Abstract To date, functional magnetic resonance imaging (fMRI) studies of the lateral geniculate nucleus (LGN) have primarily focused on measures of the blood oxygenation level dependent (BOLD) signal. Arterial spin labeling (ASL) is an MRI method that can provide direct measures of functional c

Limitations of the zero crossing detecto
✍ Di Mario, Carlo ;Roelandt, Jos R. T. C. ;De Jaegere, Peter ;Linker, David T. ;Oo 📂 Article 📅 1993 🏛 John Wiley and Sons 🌐 English ⚖ 943 KB

The current clinical standard for the analysis of intracoronary Doppler signals is the application of a zero-crossing (ZC) detector. However, the accuracy of the method is questionable, especially in areas of disturbed flow, as confirmed by in vitro studies, animal experiments, and intraoperative ob

The impact of increased mean airway pres
✍ Christian Kolbitsch; Ingo H. Lorenz; Christoph Hörmann; Michael Schocke; Christi 📂 Article 📅 2000 🏛 John Wiley and Sons 🌐 English ⚖ 282 KB 👁 2 views

Contrast-enhanced magnetic resonance imaging (MRI) measurement of cerebral perfusion is a diagnostic procedure increasingly gaining access to clinical practice not only in spontaneously breathing patients but also in mechanically ventilated patients. Effects of increased mean airway pressure on cere