Eleven phenothiazine derivatives with heavy side chains contained in human whole blood have been analyzed by high-performance liquid chromatography (HPLC)/electrospray (ES) tandem mass spectrometry (MS). All compounds gave the base peaks due to [M 1] by HPLC/ES single MS. The product ions formed from each quasi-molecular ion by HPLC/ES tandem MS showed the base peaks due to side chains liberated. The mass chromatography of HPLC/ES tandem MS showed much higher sensitivity than that of HPLC/ES single MS for phenothiazines spiked to whole blood. Therefore, regression equations, detection limits, recovery rates and reproducibility were studied for thiethylperazine, clospirazine and flupentixol spiked to human whole blood by means of mass chromatography of HPLC/ES tandem MS. The three compounds showed good linearity in the range of 2-40 ng/mL with a detection limit of about 0.5 ng/mL. Recoveries of the three compounds spiked to whole blood (2 and 8 ng added to 1 mL whole blood) were 43.4-72.5 %; the coefficients of intraday and interday variations were 3.7-9.3 and 12.6-17.9 %, respectively. Thiethylperazine, clospirazine and flupentixol in whole blood could actually be determined with sufficient sensitivity 3 and 6 h after oral administration of 5-10 mg of each compound in a volunteer.


๐Ÿ“œ SIMILAR VOLUMES


High-performance liquid chromatography c
โœ Mi-cong Jin; Xiao-kun OuYang; Xiao-hong Chen ๐Ÿ“‚ Article ๐Ÿ“… 2006 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 229 KB ๐Ÿ‘ 1 views

## Abstract A highโ€performance liquid chromatographicโ€“tandem mass spectrometric (HPLCโ€“MSโ€“MS) assay was developed and validated to determine quantitatively flocoumafen and brodifacoum in whole blood using warfarin as an internal standard (IS). Liquidโ€“liquid extraction, using ethyl acetate, was used

Clonazepam quantification in human plasm
โœ Luiz E. Cavedal; Fabiana D. Mendes; Claudia C. Domingues; Anil K. Patni; Tausif ๐Ÿ“‚ Article ๐Ÿ“… 2007 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 244 KB ๐Ÿ‘ 1 views

## Abstract A rapid, sensitive and specific method for quantifying clonazepam in human plasma using diazepam as the internal standard (IS) is described. The analyte and the IS were extracted from plasma by liquidโ€liquid extraction using a hexane/diethylether (20 : 80, v/v) solution. The extracts we

Quantitative determination of Ecteinasci
โœ Rosing, H.; Hillebrand, M. J. X.; Jimeno, J. M.; Gรณmez, A.; Floriano, P.; Faircl ๐Ÿ“‚ Article ๐Ÿ“… 1998 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 124 KB ๐Ÿ‘ 3 views

A method was developed for the bio-analysis of Ecteinascidin 743 (ET-743) using miniaturized liquid chromatography (LC) coupled to an electrospray ionization sample inlet (TurbolonSpray) and two quadrupole mass analyzers (LC/ESI-MS/MS). Solid-phase extraction was used as a sample pretreatment proced

Quantitative Analysis of Mevinolinic Aci
โœ R. E. Calaf; M. Carrascal; E. Gelpรญ; J. Abian ๐Ÿ“‚ Article ๐Ÿ“… 1997 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 136 KB ๐Ÿ‘ 3 views

Mevinolinic acid (MVA), the major active metabolite of Lovastatin in human blood, is analysed by microbore high-performance liquid chromatography coupled to electrospray tandem mass spectrometry. Quantification is carried out by using methylmevinolinic acid (MMVA) as internal standard. Positive-and