High-performance liquid chromatographic determination of dialkyltin homologues using fluorescence detection
โ Scribed by Tai-Hong Yu; Yasuaki Arakawa
- Publisher
- Elsevier Science
- Year
- 1983
- Tongue
- English
- Weight
- 534 KB
- Volume
- 258
- Category
- Article
- ISSN
- 1873-3778
No coin nor oath required. For personal study only.
โฆ Synopsis
A simple, sensitive and reproducible method has been developed for the simultaneous determination of dialkyltin compounds and their possible metabolites. Dialkyltin compounds were separated by high-performance liquid chromatography on a cyanopropyl-bonded column with n-hexaneethyl acetate (955) containing 5% acetic acid and detected by a fluorescence detector with an excitation wavelength at cu. 420 nm and an emission wavelength at cu. 500 nm after post-column derivatization with Morin reagent. Detection limits ranged from 0.1 to 1 ng depending upon the dialkyltin species. Recoveries of dialkyltins added to various tissues at the 5nmole level ranged from 91 to 99%.
๐ SIMILAR VOLUMES
A high-performance liquid chromatographic method for the fluorometric determination of 1,2,3,4-tetrahydroisoquinoline in rat brain is described. 1,2,3,4-Tetrahydroisoquinoline and 4-phenylpiperidine (internal standard) are isolated by liquid-liquid extraction, and then converted into the correspondi