High-Frequency Ultrasound Properties of Multicellular Spheroids During Heating

โœ Scribed by M.R. Gertner; B.C. Wilson; M.D. Sherar


Publisher
Elsevier Science
Year
1998
Tongue
English
Weight
392 KB
Volume
24
Category
Article
ISSN
0301-5629

No coin nor oath required. For personal study only.

โœฆ Synopsis


High-frequency ultrasound monitoring is a possible method for real-time imaging of thermal therapy in tissues at microscopic resolution. The objective of this work was to measure changes in the ultrasound properties of V79 spheroids (grown from Chinese Hamster lung fibroblasts) exposed to heating. Spheroids are clonal aggregates of cells that provide a useful model for investigating the ultrasound properties of cells in the absence of connective tissue. Relative echo signal power and attenuation coefficients were measured over the frequency range 30 MHz to 70 MHz, from spheroids heated from 37ยฐC to 50ยฐC or 60ยฐC. Echo signal power from the viable rim decreased during the first 5 min by a factor of 1.08 before the spheroid reached 50ยฐC. For the next 25 min, echo signal power rose to a factor of 1.27 above the initial level, after which it remained relatively constant over the remainder of the 50ยฐC heating period. At 60ยฐC, echo signal from the viable rim remained relatively constant, although it appeared to have possibly decreased slightly over the duration of the heating period. Echo signal power from the necrotic core fell to a factor of 1.4 and 1.54 below the initial level at 50ยฐC and 60ยฐC, respectively. First-order chemical rate analysis applied to the echo signal power results in the viable rim at 50ยฐC revealed a rate constant for the 5-15-min heating interval. Interpretation of the echo signal power results in terms of histological stains indicates that the rise in echo signal power at 50ยฐC was due to a loss of cell cohesion, and the possible drop in echo signal power at 60ยฐC was due to spheroid coagulation. Attenuation coefficients decreased by up to 1.54 dB mm ุŠ1 over a 30-min period at 60ยฐC. The appearance of a real-time ultrasound image of lesion formation in cells is discussed.


๐Ÿ“œ SIMILAR VOLUMES


Ultrasound properties of liver tissue du
โœ M.R. Gertner; B.C. Wilson; M.D. Sherar ๐Ÿ“‚ Article ๐Ÿ“… 1997 ๐Ÿ› Elsevier Science ๐ŸŒ English โš– 836 KB

The objective of this work was to determine changes in the ultrasound properties of heated tissues, with potential application to monitoring of minimally invasive thermal therapy (MITT). Changes in backscatter coefficients and frequency-dependent attenuation coefficients were measured over the frequ

Efficacy of a heat and moisture exchange
โœ D. F. Zandstra; C. P. Stoutenbeek; D. R. Miranda ๐Ÿ“‚ Article ๐Ÿ“… 1987 ๐Ÿ› Springer ๐ŸŒ English โš– 253 KB

A hygroscopic condensor humidifier has been tested during high-frequency jet ventilation, in an experimental set up. The influence of various ventilator settings on relative humidity, temperature and water content of the inspiratory and expiratory gases was investigated. The device provides adequate