## Abstract ## Purpose: To evaluate the diagnostic ability of diffusion‐weighted imaging (DWI) and dynamic contrast‐enhanced imaging (DCEI) in combination with T2‐weighted imaging (T2WI) for the detection of prostate cancer using 3 T magnetic resonance imaging (MRI) with a phased‐array body coil.
High-contrast 3D neonatal brain imaging with combined T1- and T2-weighted MP-RAGE
✍ Scribed by John Conklin; Jeff D. Winter; R. Terry Thompson; Neil Gelman
- Publisher
- John Wiley and Sons
- Year
- 2008
- Tongue
- English
- Weight
- 423 KB
- Volume
- 59
- Category
- Article
- ISSN
- 0740-3194
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Optimization of magnetization‐prepared rapid gradient‐echo (MP‐RAGE) sequence variations for maximum white matter (WM) versus gray matter (GM) contrast in neonates at 3T was investigated. Numerical simulations were applied to optimize and compare three contrast preparation modules and to assess the effect of phase encoding (PE) order on contrast between WM and thin cortical GM layers. Simulations predict that a new sequence, which combines both T~1~‐ and T~2~‐weighting into the contrast preparation and utilizes an interleaved elliptical‐spiral PE order, should provide the strongest contrast between neonatal WM and cortical GM. This sequence was compared to a conventional MP‐RAGE acquisition (i.e., T~1~‐weighted preparation, centric PE order) for in vivo imaging of seven preterm newborn infants. Regional measurements of the contrast‐to‐noise ratio (CNR) between WM and GM demonstrated an increase of 50–70% (depending on GM region) using the new sequence, in good agreement with theoretical predictions. This improved contrast resulted in superior WM versus GM discrimination in intensity‐based brain tissue segmentations. Magn Reson Med 59:1190–1196, 2008. © 2008 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
## Abstract __T__~1~‐weighted contrast is conventionally obtained using multislice two‐dimensional (2D) spin‐echo (SE) imaging. Achieving isotropic, high spatial resolution is problematic with conventional methods due to a long acquisition time, imperfect slice profiles, or high‐energy deposition.
## Abstract ## Purpose To assess whether the use of postcontrast fluid‐attenuated inversion recovery (FLAIR) imaging in combination with pre‐ and postcontrast magnetization transfer (MT) T1‐weighted imaging (T1WI) can increase diagnostic confidence in the evaluation of brain metastases. ## Materi
the vesselwall cells are large enough. With respect to the brain the situation is even easier. Because of the presence of the blood-brain barrier (BBB), represented mainly by endothelial tight junctions, all current available MR contrast media do not leak into the brain tissue. The BBB blocks all mo
Conventional T 2 -and T\* 2 -weighted image contrasts are produced by waiting a TE period for the transverse magnetic resonance (MR) signals to decay to differentiate tissue types with distinct relaxation rates. Significant image signal-to-noise ratio (SNR) is compromised by this contrast-producing