## Abstract A polypyrrole (Ppy)/graphene (G) composite was developed and applied as a novel coating for use in solid‐phase microextraction (SPME) coupled with gas chromatography (GC). The Ppy/G‐coated fiber was prepared by electrochemically polymerizing pyrrole and G on a stainless‐steel wire. The
Graphene-coated fiber for solid-phase microextraction of triazine herbicides in water samples
✍ Scribed by Qiuhua Wu; Cheng Feng; Guangying Zhao; Chun Wang; Zhi Wang
- Publisher
- John Wiley and Sons
- Year
- 2011
- Tongue
- English
- Weight
- 179 KB
- Volume
- 35
- Category
- Article
- ISSN
- 1615-9306
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Graphene is a novel and interesting carbon material that could be used for the separation and purification of some chemical compounds. In this investigation, graphene was used as a novel fiber‐coating material for the solid‐phase microextraction (SPME) of four triazine herbicides (atrazine, prometon, ametryn and prometryn) in water samples. The main parameters that affect the extraction and desorption efficiencies, such as the extraction time, stirring rate, salt addition, desorption solvent and desorption time, were investigated and optimized. The optimized SPME by graphene‐coated fiber coupled with high‐performance liquid chromatography‐diode array detection (HPLC‐DAD) was successfully applied for the determination of the four triazine herbicides in water samples. The linearity of the method was in the range from 0.5 to 200 ng/mL, with the correlation coefficients (r) ranging from 0.9989 to 0.9998. The limits of detection of the method were 0.05‐0.2 ng/mL. The relative standard deviations varied from 3.5 to 4.9% (n=5). The recoveries of the triazine herbicides from water samples at spiking levels of 20.0 and 50.0 ng/mL were in the range between 86.0 and 94.6%. Compared with two commercial fibers (CW/TPR, 50 μm; PDMS/DVB, 60 μm), the graphene‐coated fiber showed higher extraction efficiency.
📜 SIMILAR VOLUMES
In this paper, some theoretical and practical aspects of solid-phase microextraction coated fibers will be discussed in detail. The surfaces of a series of prepared fibers have been characterized by chromatographic methods. The Ž . following fibers were tested: ethoxy-polydimethylsiloxane coated fib
## Abstract Solid‐phase microextraction (SPME) coupled to LC for the analysis of five diphenylether herbicides (aclonifen, bifenox, fluoroglycofen‐ethyl, oxyfluorfen, and lactofen) is described. Various parameters of extraction of analytes onto the fiber (such as type of fiber, extraction time and
## Abstract A novel chemically bonded graphene oxide/fused‐silica fiber was prepared and applied in solid‐phase microextraction of six polycyclic aromatic hydrocarbons from water samples coupled with gas chromatography. It exhibited high extraction efficiency and excellent stability. Effects of ext
## Abstract The study on the performance of polyaniline as a fiber coating for solid‐phase microextraction (SPME) purposes has been reported. Polyaniline coatings were directly electrodeposited on the surface of a stainless steel wire and applied for the extraction of some organochlorine pesticides