## Abstract In arid/semi‐arid environments, where rainfall is seasonal, highly variable and significantly less than the evaporation rate, groundwater discharge can be a major component of the water and salt balance of a wetland, and hence a major determinant of wetland ecology. Under natural condit
Geophysical surveys for identifying saline groundwater in the semi-arid region of the central Altiplano, Bolivia
✍ Scribed by Roger Guérin; Marc Descloitres; Anne Coudrain; Amal Talbi; Robert Gallaire
- Publisher
- John Wiley and Sons
- Year
- 2001
- Tongue
- English
- Weight
- 668 KB
- Volume
- 15
- Category
- Article
- ISSN
- 0885-6087
- DOI
- 10.1002/hyp.284
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
In the central part of the Bolivian Altiplano, the shallow groundwater presents electrical conductivities ranging from 0·1 to 20 mS/cm. In order to study the origin of this salinity pattern, a good knowledge is required of the geometry of the aquifer at depth. In this study, geophysics has been used to complement the sparse data available from drill holes. One hundred time‐domain electromagnetic (TDEM) soundings were carried out over an area of 1750 km^2^. About 20 geological logs were available close to some of the TDEM soundings. Three intermediate results were obtained from the combined data: (i) the relationship between the electrical conductivity of the groundwater and the formation resistivity, (ii) geoelectrical cross‐sections and (iii) geoelectrical maps at various depths. The limited data set shows a relationship between resistivity and the nature of the rock. From the cross‐sections, a conductive substratum with a resistivity of less than 1 Ω·m was identified at most of the sites at depths ranging from 50 to 350 m. This substratum could be a clay‐rich formation containing brines. Using derived relationships, maps of the nature of the formation (sandy, intermediate and clayey sediments) were established at depths of 10 and 50 m. Discrimination between sand and clays was impossible where groundwater conductivity is high (>3 mS/cm). In the central part of the area, where the groundwater conductivity is low, sandy sediments are likely to be present from the surface to a depth of more than 200 m. Clayey sediments are more likely to be present in the south‐east and probably constitute a hydraulic barrier to groundwater flow. In conclusion, the study demonstrates the efficiency of the TDEM sounding method to map conductive zones. Copyright © 2001 John Wiley & Sons, Ltd.
📜 SIMILAR VOLUMES