Gas chromatographic determination of cocaine and its metabolites in blood and urine from cocaine users in northwestern Spain
✍ Scribed by P. Fernández; L. Buján; A. M. Bermejo; M. J. Tabernero
- Publisher
- John Wiley and Sons
- Year
- 2004
- Tongue
- English
- Weight
- 75 KB
- Volume
- 24
- Category
- Article
- ISSN
- 0260-437X
- DOI
- 10.1002/jat.994
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
A gas chromatographic method with flame ionization detection (GC/FID) was developed for the determination of cocaine and its metabolites in blood and urine samples from cocaine users in Northwestern Spain. After a solid‐phase extraction with Bond Elut Certify cartridges and a derivatization with bis‐trimethylsilyltrifluoroacetamide–trimethylchlorosilane (1%), calibration curves were constructed over 0.4–4 µg ml^−1^ for urine and 0.1–2 µg ml^−1^ for blood, using proadifen as the reference compound. The average extraction recoveries were 75% for urine and 78% for blood. The limits of detection and quantitation were 0.071 and 0.24 µg ml^−1^, respectively. Coefficients of variation were <10% and accuracy was within ±12%. The average blood concentrations of cocaine, benzoylecgonine and ecgonine methyl ester in 42 living patients were 0.22, 1.43 and 0.16 µg ml^−1^, respectively. Urine samples were collected from individuals in the criminal justice system (70 cases), from drug abusers admitted to emergency rooms (36 cases) and from patients under detoxification treatment (36 cases). The second group exhibited the highest average concentrations (e.g. 0.97 µg ml^−1^ for cocaine, 5.23 µg ml^−1^ for benzoylecgonine and 0.39 µg ml^−1^ for ecgonine methyl ester). Sixty‐five fatal intoxications due to cocaine alone or in combination with other drugs were studied, and average blood levels were found to be higher in the deaths related to cocaine alone (e.g. 0.40 µg ml^−1^ for cocaine, 2.38 µg ml^−1^ for benzoylecgonine and 0.38 µg ml^−1^ for ecgonine methyl ester). Copyright © 2004 John Wiley & Sons, Ltd.
📜 SIMILAR VOLUMES
Although gas chromatography/mass spectrometry (GC/MS) is the most powerful technique for analysing cocaine and its hydrolysis products (benzoylecgonine, ecgonine methyl ester and ecgonine) in urine, the sample pretreatment required is rather laborious and involves a large number of steps. This paper
Gas chromatography was used in combination with flame ionization detection (GC-FID) to develop a method for determining cocaine and its two metabolites, benzoylecgonine (BEG) and ecgonine methyl ester (EME), in bile and vitreous humor. The method used a 12 m × × × × × 0.2 mm i.d. column of 0.33 µ µ
## Abstract In this work, a simple method for the simultaneous determination of cocaine (COC) and five COC metabolites (benzoylecgonine, cocaethylene (CET), anhydroecgonine, anhydroecgonine methyl ester and ecgonine methyl ester) in human urine using CE coupled to MS __via__ electrospray ionization