𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Fused silica microcolumn LC-MS and MS/MS using an aeronebulized interface

✍ Scribed by Karl-Erik Karlsson


Publisher
John Wiley and Sons
Year
1991
Tongue
English
Weight
650 KB
Volume
3
Category
Article
ISSN
1040-7685

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

An aeronebulized interface has been developed for use with 0.15–0.25‐mm i.d. slurry‐packed fused silica columns. The interface was built in a removable probe that uses tha direct inlet on a triple quadrupole mass spectrometer for easy switching between LC, GC, or the solids probe. The probe is indirectly heated by the ion source, and premature evaporation of the mobile phase, acetonitrile/water, is prevented by controlled water cooling. A standard EI/CI ion source was used in the chemical ionization mode using methane to control the pressure in the source. Several variables that influence the performance of the interface were evaluated using various drugs as model compounds. Typically, 50,000 to 70,000 theoretical plates could be generated. The minimum detectable quantities were generally in the low picogram range. The best result was 3 pg using negative ion SIM, corresponding to a concentration of 8 Γ— 10^βˆ’8^ M in the injected sample.


πŸ“œ SIMILAR VOLUMES


Fused silica open-split GS/MS interface
✍ Pankow, J. F. ;Isabelle, L. M. πŸ“‚ Article πŸ“… 1987 πŸ› John Wiley and Sons 🌐 English βš– 183 KB
Probing the substrate specificity of an
✍ Bateman, Kevin P.; Thibault, Pierre; Yang, Keqian; White, Robert L.; Vining, Leo πŸ“‚ Article πŸ“… 1997 πŸ› John Wiley and Sons 🌐 English βš– 451 KB

LC-MS and LC-MS/MS analyses indicated that an enzyme responsible for inactivating the antibiotic etamycin is speciÐc for streptogramins and acts on both type B-I and B-II streptogramin subgroups. No enzymatic activity was detected for other cyclodepsipeptides such as surfactins and viscosin. It was

Strategies for compound identification a
✍ Colby, B. N. ;Ryan, P. W. ;Wilkinson, J. E. πŸ“‚ Article πŸ“… 1983 πŸ› John Wiley and Sons 🌐 English βš– 423 KB

## Abstract A test mixture containing 28 compounds plus their stable isotopically labeled analogs was analyzed on a daily basis for one month during a series of routine fused silica capillary column GC/MS analyses in order to establish the precision with which retention times and responses were pro

Extraction of ketamine from urine using
✍ Tarang Nema; Eric C. Y. Chan; Paul C. Ho πŸ“‚ Article πŸ“… 2011 πŸ› John Wiley and Sons 🌐 English βš– 189 KB

## Abstract The high surface area monolith with reactive hydroxyl group on its surface enables it to function as a miniature solid‐phase extraction (SPE) cartridge in size of 1 cm in diameter and 0.5 cm in length. The prepared silica monolith was characterized by Brunauer–Emmett–Teller method, scan