A commercially available nonpremixed pulsed combustion room heater designed to burn natural gas has been used to study the effect of gas composition on the operational characteristics of the combustor. Three parameters have been monitored as fuel flowrates and gas composition were varied, viz., the
Frequency evaluation of a gas-fired pulse combustor
โ Scribed by Ali Kilicarslan
- Publisher
- John Wiley and Sons
- Year
- 2005
- Tongue
- English
- Weight
- 142 KB
- Volume
- 29
- Category
- Article
- ISSN
- 0363-907X
- DOI
- 10.1002/er.1069
No coin nor oath required. For personal study only.
โฆ Synopsis
Theoretical study and experimental investigation of a Helmholtz-type gas-fired pulse combustor are presented. In this study, a mathematical model was developed to evaluate the operating frequency of the pulse combustor. A variety of experiments were also performed to prove the validation of theoretical frequency model and compare the theoretical frequency with the experimental one.
In the experiments, the length and diameter of the tail pipe, the volume of the combustion chamber and the gas supply pressure of the combustor were changed within certain limits. In the experiments, related to tailpipe length, there was a perfect agreement between the tailpipe lengths of 1.2 and 1.6 m. As the theoretical frequency was compared with the experimental one, the maximum deviation was 5.8 Hz (1.25% errors). If the frequency comparisons related to the volume of the combustion chamber were taken into consideration, the calculated frequency and measured ones agreed very closely. In the volumes between 1/2 V c and V c , maximum deviation was 5.4 Hz (7.7% errors). In this study, a tunable pulse combustor, which is used for increasing the frequency of industrial processes, was also developed.
๐ SIMILAR VOLUMES
A non-linear model has been developed for a gas-fired furnace in which oil is heated. The model is applicable from minimum to maximum heat load of the furnace. The dynamics of the model have been compared to experimental results, which were obtained for a pilot-scale furnace. They are in good agreem
The appearance of nonlinear acoustic oscillations in pulse combustors and other unsteady combustion devices arises from combustion-driven instabilities that excite one or more classical acoustic modes of the system. For sufficiently strong acoustic driving relative to various damping processes, thes