## Abstract In the present study, the heat transfer coefficients occurring with a projection in the turbulent region of a vertical flat plate were measured experimentally for various projection heights in the range of 0 to 20 mm. The wall temperature and fluid flow fields were also visualized using
Freezing heat transfer along a horizontal cooled plate with a separated region
โ Scribed by Yamada, Masahiko ;Fukusako, Shoichiro ;Kawanami, Tsuyoshi ;Kurita, Masanori ;Oh, Cheol
- Publisher
- John Wiley and Sons
- Year
- 1998
- Tongue
- English
- Weight
- 204 KB
- Volume
- 27
- Category
- Article
- ISSN
- 0096-0802
No coin nor oath required. For personal study only.
โฆ Synopsis
Experiments were carried out to determine the effect of flow separation on freezing heat transfer characteristics along a horizontal cooled flat plate immersed within a rectangular duct. The flow separation was induced by a vertically situated thin plate placed against the flow at the leading edge of a uniformly cooled plate. The degree of flow separation was altered by employing vertical plates of various heights. The Reynolds number and the cooling temperature ratio ranged from 5.6 ร 10 2 to 8.4 ร 10 4 and from 3.0 to 10.0, respectively. The measurements showed that the flow separation exerts a marked influence on the local ice formation characteristics. Two kinds of ice formation of convex and concave profiles were observed to occur as a function of the Reynolds number, as well as of the cooling temperature ratio.
๐ SIMILAR VOLUMES
## Abstract This study conducts numerical analyses and experiments on natural convection heat transfer in eccentric horizontal annuli between a heated outer tube and a cooled inner tube with different orientations. The outer tube is an elliptical tube, and the inner tube is a cylindrical tube. Expe