𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Free electron laser ablation of articular and fibro-cartilage at 2.79, 2.9, 6.1, and 6.45 μm: Mass removal studies

✍ Scribed by Jong-In Youn; George M. Peavy; Vasan Venugopalan


Publisher
John Wiley and Sons
Year
2005
Tongue
English
Weight
172 KB
Volume
36
Category
Article
ISSN
0196-8092

No coin nor oath required. For personal study only.

✦ Synopsis


Background and Objective: The wavelength and tissuecomposition dependence of cartilage ablation was examined using selected mid-infrared laser wavelengths. Study Design/Materials and Methods: The mass removal produced by pulsed laser ablation of articular and fibro-cartilage (meniscus) were measured. The wavelengths examined were 2.79, 2.9, 6.1, and 6.45 mm and provided by a free electron laser (FEL) emitting 4 msecond macropulses consisting of 1-2 picoseconds duration micropulses delivered at 350 picosecond intervals. The measurement of tissue mass removal was conducted using a microbalance during laser ablation. Results: These studies demonstrated that for articular cartilage the highest mass removal was achieved at l ¼ 6.1 mm followed by, in order, l ¼ 2.79, 2.9, and 6.45 mm. In comparison, the maximum mass removal for fibro-cartilage was achieved using l ¼ 6.1 mm radiation with no statistically significant differences in mass removal provided by the other wavelengths. In evaluation of the comparative influence of each wavelength on tissue type, there was no difference in ablation efficiency between articular and fibro-cartilage at l ¼ 6.1 mm. However, the ablation efficiency of articular cartilage was higher than that of fibro-cartilage at both l ¼ 2.79 and 2.9 mm. By contrast, l ¼ 6.45 mm radiation ablated fibro-cartilage more efficiently than articular cartilage at radiant exposures greater than 12 J/cm 2 . Conclusions: The mass removal of articular and fibrocartilage produced by FEL ablation at selected mid-IR wavelengths was measured as a function of incident radiant exposure. The ablation efficiency was found to depend on both wavelength and tissue type. The 6.1 mm wavelength was found to provide the highest ablation efficiency for both articular and fibro-cartilage. Lasers


📜 SIMILAR VOLUMES


A comparison of mass removal, thermal in
✍ Jong-In Youn; Paula Sweet; George M. Peavy 📂 Article 📅 2007 🏛 John Wiley and Sons 🌐 English ⚖ 315 KB

## Abstract ## Background and Objective Previous investigations have reported evidence of wavelength dependence on cortical bone ablation. This study used mid‐infrared laser wavelengths generated by a free electron laser (FEL) and mass removal measurements to further examine the ablation efficienc