𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Four-dimensional transcatheter intraarterial perfusion (TRIP)-MRI for monitoring liver tumor embolization in VX2 rabbits

✍ Scribed by Dingxin Wang; Sumeet Virmani; Richard Tang; Barbara Szolc-Kowalska; Gayle Woloschak; Reed A. Omary; Andrew C. Larson


Publisher
John Wiley and Sons
Year
2008
Tongue
English
Weight
962 KB
Volume
60
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Transcatheter intraarterial perfusion (TRIP)‐MRI is an intraprocedural technique to iteratively monitor liver tumor perfusion changes during transcatheter arterial embolization (TAE) and chemoembolization (TACE). However, previous TRIP‐MRI approaches using two‐dimensional (2D) T~1~‐weighted saturation‐recovery gradient‐recalled echo (GRE) sequences provided only limited spatial coverage and limited capacity for accurate perfusion quantification. In this preclinical study, a quantitative 4D TRIP‐MRI technique (serial iterative 3D volumetric perfusion imaging) with rigorous radiofrequency (RF) B~1~ field calibration and dynamic tissue longitudinal relaxation rate R~1~ measurement is presented for monitoring intraprocedural liver tumor perfusion during TAE. 4D TRIP‐MRI and TAE were performed in five rabbits with eight VX2 liver tumors (N = 8). After B~1~ calibrated baseline and dynamic R~1~ quantification, subsequent tissue contrast agent concentration time curves were derived. A single‐input flow‐limited pharmacokinetic model and peak gradient method were applied for perfusion analysis. The perfusion __F__ρ reduced significantly from pre‐TAE 0.477 (95% confidence interval [CI]: 0.384–0.570) to post‐TAE 0.131 (95% CI: 0.080–0.183 ml/min/ml, P < 0.001). Magn Reson Med 60:970–975, 2008. © 2008 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Four-dimensional transcatheter intra-art
✍ Johnathan C. Chung; Dingxin Wang; Robert J. Lewandowski; Richard Tang; Howard B. 📂 Article 📅 2010 🏛 John Wiley and Sons 🌐 English ⚖ 956 KB

## Abstract ## Purpose: To test the hypothesis that four‐dimensional (4D) transcatheter intra‐arterial perfusion (TRIP) MR imaging can measure uterine fibroid perfusion changes immediately before and after uterine artery embolization (UAE) in the rabbit VX2 tumor model. ## Materials and Methods:

Comparison between intravenous and intra
✍ Andrew C. Larson; Thomas K. Rhee; Jie Deng; Dingxin Wang; Kent T. Sato; Riad Sal 📂 Article 📅 2006 🏛 John Wiley and Sons 🌐 English ⚖ 465 KB

## Abstract ## Purpose To test the hypothesis that catheter‐directed intraarterial (IA) contrast agent injection increases tumor enhancement and conspicuity compared to intravenous (IV) injection. ## Materials and Methods Eight VX2 liver tumors were grown in five rabbits. After positioning a cat