A sapphire cylinder, of 100 mm diameter and 60 mm length, was suspended on a pair of sapphire fibers to simulate a mirror for a cryogenic laser interferometric gravitational wave detector. A mechanical quality factor of 2.5 = 10 8 was obtained for the second axial symmetric mode of the cylinder at 4
โฆ LIBER โฆ
Force measurements of a superconducting-film actuator for a cryogenic interferometric gravitational-wave detector
โ Scribed by N. Sato; T. Haruyama; N. Kanda; K. Kuroda; S. Miyoki; M. Ohashi; Y. Saito; T. Shintomi; T. Suzuki; D. Tatsumi; C. Taylor; T. Tomaru; T. Uchiyama; A. Yamamoto
- Publisher
- Elsevier Science
- Year
- 2003
- Tongue
- English
- Weight
- 269 KB
- Volume
- 43
- Category
- Article
- ISSN
- 0011-2275
No coin nor oath required. For personal study only.
โฆ Synopsis
We measured forces applied by an actuator with a YBa 2 Cu 3 O 7 (YBCO) film at near 77 K for the Large-scale Cryogenic Gravitational-wave Telescope (LCGT) project. An actuator consisting of both a YBCO film of 1.6 lm thickness and 0.81 cm 2 area and a solenoid coil exerted a force of up to 0.2 mN on a test mass. The presented actuator system can be used to displace the mirror of LCGT for fringe lock of the interferometer.